PDS 7000 ET ETC Série Manuel De L'utilisateur page 52

Masquer les pouces Voir aussi pour 7000 ET ETC Série:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

Dispenser 7550
SETTING UP
Connect the air supply line at the end of the regulator filter. Adjust the
1
manometer at a pressure by between 80 and 100 psi (5,5 to 6,9 bar).
We advice you to use a 5 microns filter : FLT05 or FLT01A (dehumidifier)
2
Connect the air supply line to the dispenser.
3
Hook up the foot-switch.
Check the voltage label at the back of the dispenser. Make sure that the
4
tension indicated corresponds well to your equipments. Install the power
cord.
5
Choose the adaptor which correspond to the syringe.
Press the adaptor male fitting in the female fitting located at the front of
6
the dispenser. Turn clockwise in order to block.
During the initial test, you must not use the venturi system. Keep the
7
venturi system off.
8
Connect the pen and hook up the male adaptor in the female adaptor in the
front face of the equipment. Lock out clockwise. Choose and set a plunger
on the stylus.
52

Publicité

Chapitres

Table des Matières
loading

Table des Matières