Fig. 5A
C
The sector valve can be modified to be operated from the sides
of the stove. To do so the rear screw (A) has to be removed and
the stoppers (B) be placed at one of the other screws (C).
Fig. 5B
With top outlet.
Fig. 6A
Heat storage system (cat.no. 10026701)
With top outlet (Fig. 6A):
1. Mount the flue pipe with the gasket (see Fig.4).
2. Start with the element that has premounted legs.
3. Adjust the legs until the element is stable.
4. Place the remaining elements.
20
A
B
C
Fig. 6B
Heat storage system (cat.no. 10026701)
With rear outlet (Fig. 6B):
1. Start with the element that has premounted legs.
2. Adjust the legs until the element is stable.
3. Place the remaining elements.
Fig. 7
B
A
1. Replace the sector valve (C) by placing it towards the rear end
of the side panels. The valve should rest on the flanges inside
the side panels (D) (see Fig. 7.2).
2. Mount the front panel (A) and tighten the screws (B).
C
D