Dometic FreshWell3000
6.4

Air conditioning modes

The under-bench air conditioner has the following air conditioning modes:
Air condition-
ing mode
Automatic
Cooling
Heat Pump
Circulating air
Dehumidification
Current room
temperature ϑ
Set point:
Conditioning
mode:
EN
Display
Explanation
message
In this mode the under-bench air conditioner sets
the temperature (set point) automatically and
manages the compressor, heat pump and fan
speed by comparing the set point with the room
temperature and it sets the corresponding condi-
tioning mode (see following table).
The
mode.
You specify the temperature and blower settings,
and the under-bench air conditioner cools the
interior to this temperature.
You specify the temperature and blower settings,
and the under-bench air conditioner heats the
interior to this temperature.
You specify the blower level, and the under-
bench air conditioner blows air into the interior
You specify the temperature, and the under-
bench air conditioner cools the interior to this
temperature and controls the necessary blower
output and dehumidifys the interior (Circulating
air mode).
The
ϑ ≤ 20 °C
20 °C
Heat Pump or
Circulating air
Technical description
, + and – buttons are deactivated in this
button is deactivated in this mode.
22 °C < ϑ < 25 °C
22 °C
Dehumidification or
Circulating air
.
ϑ ≥ 25 °C
25 °C
Cooling
17