Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

FU NC T I O N BU T TO N S
ON / OFF switch – When plugging in the appliance, a signal will sound and
the appliance will go to standby mode. When pressing the ON/OFF switch,
the LED-display will illuminate and the appliance is operational. Pressing the
ON/OFF switch once again will turn the appliance back to standby mode.
AUTO button – Pressing this button will turn the appliance to automatic
mode. The appliance will register the current air humidity of the room and
bring it to resp. maintain it constant between 55% and 68%.
Humidification capacity button – You can personally set nebulisation
intensity – you can choose between three humidiication / capacity levels:
¡
low
, intermediate
midiication capacity, the display will state the particular symbols
If you turn off the warm mist function the outlet nozzles will atomise
cold mist.
Air humidity button – With this button you can manually set air humidity
in the room. You can program any value between 40% and 80% in intervals
of 5%. The appliance will register current air humidity of the room, bring it
to the set value and maintain it constant.
An example: When you set air humidity to 50% the appliance will check am-
bient air humidity. If air humidity in the room is below 50%, the humidiier
will begin operation. If air humidity is at or above 50%, the appliance will
stop operation.
The appliance is equipped with a built-in humidity switch, guaranteeing
that user programmed air humidity is permanently maintained. The humid-
ity switch will continuously meter air humidity at intervals of 3–5 minutes.
Should effective air humidity drop 4% below the value set by you, the ma-
chine will turn on. This tolerance is picked deliberately to keep the appliance
from turning on and off frequently and disturbingly. This is also why your
appliance is programmed so that time in between two turn-on processes is
at least 3 minutes.
In our example this would mean: Should air humidity in the room drop below 46%
(this value exceeds the tolerance of 4%), the appliance would turn back on not later
than 3–5 minutes and return air humidity to 50%.
NOTE: When the appliance is turned on (regardless of whether the power
supply has been disrupted or not) it will start operating for at least 1 minute
to meter current air humidity, even if effective air humidity is above the set
value. After that, the appliance will either keep operating - if the value is be-
low 50%, as in our example - or discontinue operation - if the value is above
50%, as in our example.
"
and high
. Every touch of the button will change hu-
¡
"
,
or
.
63

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Ultrasonic hybridSh8410721496992

Table des Matières