2.2 Incorrect purpose
of use
3. Technical data
3.1 Connection and
power values
3.2 Ambient conditions
during operation
3.3 Dimensions and
weights
4. Safety
4.1 Safety notes and
symbols in these
instructions
18
Any use that is not mentioned in chapter 2.1 is considered to be improper.
The operator is solely responsible for any resulting damage. It is particularly
important to avoid the following:
• Use in potentially explosive environments
• Use in the vicinity of electromagnetically sensitive devices
• Use in aggressive environments (containing salt or chlorine, for example)
• Omitting components during installation
• Changes to the installation order
• Use of non-original parts
• Use of defective or damaged components
• Modifications or repairs to the product
Voltage
Current consumption, max. at
(12 V)
Power consumption, max.
Operating temperature
Rel. humidity, max.
Degree of protection (front)
Degree of protection (rear)
Dimensions
Installation depth
(without cable)
Safety notes
Safety notes in these instructions follow a uniform structure. They are introduced by
a signal word that indicates the extent of the hazard. This is followed by the source
of the danger and measures to avoid them.
The following risk levels are distinguished:
DANGER
This combination of symbol and signal word indicates an immediately
dangerous situation causing death or serious injury if not avoided.
WARNING
This combination of symbol and signal word indicates a potentially
dangerous situation that may cause death or serious injury if not avoided.
12 V to 24 V DC, ± 15 %
0.2 A
3 W
-25 °C – +70 °C
10 – 95 %, not condensed
IP 65
IP 44
H 81 mm x W 81 mm x D 15 mm
35 mm