BATTERY GUIDE
The Energizer will automa cally reduce its power usage if the ba ery is star ng to
go fl at. This will be achieved by reducing the energy in each pulse and increasing
the interval between pulses.
Number of Pulses per minute
If the energizer is in alarm, wait for this to clear before es ma ng ba ery capacity.
The Energizer stops pulsing if the ba ery drops below 20% to prevent damaging the
ba ery.
Gallagher Recommends:
Use 12 V deep cycle lead acid ba eries.
Ba eries of the same type and manufacturer can be connected in parallel to
increase capacity.
Store ba ery in a dry place between 0
Do not leave ba eries below 50% charge (12.0 V) for a prolonged period of
me.
Ba eries must be in a well ven lated area while charging.
Ba eries must be disconnected from the energizer while charging.
Full Power Opera on
12
Gallagher 3E4348 MB1000 Energizer User Manual
30
20
15
6
2 days
4 days
6 days
Ba ery Capacity
75% +
60 - 70%
25 - 60%
20 - 25%
o
C and 30
o
C.
Ba ery Capacity Required
100 Ah
200 Ah
300 Ah