Main Remote Controller; Main Screen - Mitsubishi Electric ecodan EHPT Série Manuel D'installation

Masquer les pouces Voir aussi pour ecodan EHPT Série:
Table des Matières

Publicité

5
System Set Up

5.7 Main remote controller

To change the settings of your heating/cooling system please use the main re-
mote controller located on the front panel of the cylinder unit or hydrobox. The
following is a guide to viewing the main settings. Should you require more infor-
mation please contact your installer or local Mitsubishi Electric dealer.
Cooling mode is available for ERS series only. However, Cooling mode is not
available when the indoor unit is connected to PUHZ-FRP.
F1
F2
B
C
12
15
10
9
8
7
F3
F4
D
14
11
1
17
2
3
6

Main screen

<Main remote controller parts>
Letter
Name
A
Screen
B
Menu
C
Back
D
Confirm
E
Power/Holiday
F1-4
Function keys
A
*1
When the system is switched off or the power supply is disconnected, the
cylinder unit protection functions (e.g. freeze stat. function) will NOT oper-
ate. Please beware that without these safety functions enabled the cylinder
unit may potentially become exposed to damage.
<Main screen icons>
Icon
1
Legionella
prevention
E
2
Heat pump
3
Electric heater
16
4
Target
temperature
5
OPTION
6
+
7
-
8
Z1
13
Information
4
9
Space heating/
cooling mode
10
DHW mode
11
Holiday mode
12
5
13
Current
temperature
14
15
16
Buffer tank
control
17
Smart grid ready
*2 This unit is in Stand-by whilst other indoor unit(s) is in operation by
priority.
*3 T o lock or unlock the Menu, press the BACK and CONFIRM keys
simultaneously for 3 seconds.
Function
Screen in which all information is displayed
Access to system settings for initial set up and
modifications.
Return to previous menu.
Used to select or save. (Enter key)
If system is switched off pressing once will turn
system ON. Pressing again when system is
switched on will enable Holiday Mode. Holding the
button down for 3 seconds will turn the system off.
(*1)
Used to scroll through menu and adjust settings.
Function is determined by the menu screen visible
on screen A.
Description
When this icon is displayed 'Legionella prevention
mode' is active.
'Heat pump' is running.
Defrosting
Emergency heating
'Quiet mode' is activated.
When this icon is displayed the 'Electric heaters'
(booster or immersion heater) are in use.
Target flow temperature
Target room temperature
Compensation curve
Pressing the function button below this icon will dis-
play the option screen.
Increase desired temperature.
Decrease desired temperature.
Z2
Pressing the function button below this icon switch-
es between Zone1 and Zone2.
Pressing the function button below this icon displays
the information screen.
Heating mode
Zone1 or Zone2
Cooling mode
Zone1 or Zone2
Normal or ECO mode
When this icon is displayed 'Holiday mode' activated.
Timer
Prohibited
Server control
Stand-by
Stand-by (*2)
Stop
Operating
Current room temperature
Current water temperature of DHW tank
The Menu button is locked or the switching of the
operation modes between DHW and Heating opera-
tions are disabled in the Option screen.(*3)
SD memory card is inserted. Normal operation.
SD memory card is inserted. Abnormal operation.
When this icon is displayed 'Buffer tank control' is
active.
When this icon is displayed, 'Smart grid ready' is
active.
en
20

Hide quick links:

Publicité

Table des Matières
loading

Table des Matières