1. Operating instructions

The installation and use of electrical appliances
must be carried out with due caution in order
to avoid the risk of fire, electric shock or injury.
The equipment must only be used as described
in these instructions. Any use outside of the
manufacturer recommendations could lead to
damage, fire, shock or injury.
The heat requirement of the room should be
matched to the heat output of the unit.
Before using the appliance the instructions
should be read in their entirety and all ap-
propriate handling of the equipment must be
observed.
These instructions should be kept safe-
!
ly and passed on to any future owner.
In the event of any repair work, hand them
to the qualified installer for his attention.
The most important points
in brief
BHC 175
2
5
1/2 h
1 h
1/4 h
2 h
3
4
1
BHC 175 L
1/2 h
1/2 h
1/2 h
1/2 h
1/2 h
1/2 h
1/2 h
1/2 h
1/2 h
1 h
1 h
1 h
1 h
1 h
1 h
1 h
1 h
1 h
1/4 h
1/4 h
1/4 h
1/4 h
1/4 h
1/4 h
1/4 h
1/4 h
1/4 h
2 h
2 h
2 h
2 h
2 h
2 h
2 h
2 h
2 h
1
3
ON/OFF button
1
2
LED indicator "appliance ON"
3
Room thermostat
(electric operation)
4
LED indicator "appliance heating up"
5
LED indicator "rapid heating function"
6
Short-time timer for "rapid heating
function"
7
ON/OFF button for "rapid heating
function"
S1 ON/OFF switch for immersion
heater
V1 LED indicator light "immersion
heater operating"
10
for users and contractors

1.1 Unit description

The BHC thermofan duo towel rail radiator is
suitable for use as full or supplementary heat-
ing as well as for drying and warming towels.
There are several levels for hanging these.
The units can be operated either as electric
room heaters or as heating elements within a
hot water central heating system.
During operation, the room air over the
surface of the heating element is heated and
distributed through the room by natural con-
vection.
The unit also has a time-limited electric
rapid heater (1000 W) with fan that can be
switched on when required.
The electrical connection is by means of mains
plug.
Operation with a hot water central
heating system
Even when the central heating is switched
off, the heating element can be heated via
6
the integral electric Direct immersion heater
(750 W) fitted as standard (see 1.3.2 Summer
operation).
Do not operate the immersion heater
!
unless the radiator is full; otherwise
the radiator will be damaged.
1.2 Operation as an electric
7
room heater
The BHC is fully controlled via the control
6, 7
panel on the front after the Direct immersion
heater has been switched on using switch S1.
The heater is be switched on via the ON/
OFF button (1). Set the room temperature to
between approx. + 6 °C and + 30 °C on the
4
room thermostat (3).
After the adjusted ambient temperature has
been reached, it will remain constantly, until the
appliance is switched off (the heating capacity
of the appliance must correspond at least to
the necessary heat requirement of the room).
Rapid heating function
With the rapid-heating-function the imersion
heater (if switch on) and the rapid-heater
(A2) will run for the preselected period for
continuous operation, regardless of the tem-
perature set on the room thermostat.
The heating time can be set to ¼ h, ½ h, 1 h
or 2 h at timer (6) and is activated by pressing
quick heat-up key (7).
V1
If the heating time is to be ended before the
end of the set period, the rapid heating button
must be pressed again.
Frost protection
In the event of a lengthy absence, the room
S1
temperature should not fall below approx.
+6 °C (frost protection) and the room ther-
mostat should be turned to the à position
and the appliance must remain switched on
(observe the heating capacity of the appliance
and heat requirement of the room).
1.3 Operation in a central
heating system
1.3.1 Winter operation
The central hot-water heating system is op-
erating.
The temperature of the BHC is controlled by
means of the thermostatic valve installed site
wise.
The electrical rapid heater can be switched on
via the control panel.
Rapid heating function
Switch on the ON/OFF button (1).
In addition, the rapid heating function can be
used to switch on the rapid heater (A2) for a
pre-selected period.
The heating time can be set to ¼ h, ½ h, 1 h
or 2 h at timer (6) and is activated by pressing
quick heat-up key (7).
If the heating time is to be ended before the
end of the set period, the rapid heating button
must be pressed again.
Frost protection
In the event of a lengthy absence, the room
temperature should not fall below approx.
+6 °C (frost protection) and the thermostatic
valve should be turned to the à position
(observe the heating capacity of the appliance
and heat requirement of the room).
1.3.2 Summer operation
The BHC is fully controlled via the control
panel on the front after the Direct immersion
heater has been switched on using switch S1.
The heater is be switched on via the ON/OFF
button (1). Set the room temperature to
between approx. + 6 °C and + 30 °C on the
room thermostat (3).
After the adjusted ambient temperature has
been reached, it will remain constantly, until the
appliance is switched off (the heating capacity
of the appliance must correspond at least to
the necessary heat requirement of the room).
Rapid heating function
With the rapid-heating-function the imersion
heater (if switch on) and the rapid-heater
(A2) will run for the preselected period for
continuous operation, regardless of the tem-
perature set on the room thermostat.
The heating time can be set to ¼ h, ½ h, 1 h
or 2 h at timer (6) and is activated by pressing
quick heat-up key (7).
If the heating time is to be ended before the
end of the set period, the rapid heating button
must be pressed again.
Frost protection
In the event of a lengthy absence, the room
temperature should not fall below approx.
+6 °C (frost protection) and the room ther-
mostat should be turned to the à position
and the appliance must remain switched on
(observe the heating capacity of the appliance
and heat requirement of the room).