SYSTEM FOR AN OPEN TANK INSTALLATION
AN EXAMPLE OF A HYDRAULIC SYSTEM FOR A THERMO FIREPLACE THAT DOES NOT PRODUCE HOT SANITARY WATER BUT HAS A WALL MOUNTED BOILER
TC
Kit 2 is designed to facilitate the work carried out by the installers. In fact, it consists of all the necessary components for the
product to be properly installed.
NB: insulating mats must be applied so that the components of the kit are well-protected from the heat radiation emitted by the
fireplace.
Components KIT 2
Electrical Connections
Circulators enabled
Alimentazione
230 Vac
Circolatore A
THE INLET AND OUTLET PIPES MUST BE CROSSED FOR THE KIT TO FUNCTION PROPERLY
KIT 2
Fuse
Display
20 - 80° C
Circulators Setting
Overheating alarm
Circulators Setting
Minimum temperature setting
for circulators to be actuated
20 – 80° C
Sonda
(inserire
nell'apposito
pozzetto)
Circolatore B
Regulator
(included in the kit)
The sales codes are in brackets ( )
OFF
ON
Enable
Disable
Acoustic
Alarm
USING
AF:
Cold Water
CA:
Wall Mounted Boiler
MI:
System Flow
P:
Pump (circulator)
RA:
Radiators
RE:
Electronic Regulator
RI:
System Return
S:
Drain
Ja:
Automatic Relief Valve
Sc 30:
30-plate Heat Exchanger
ST:
Temperature Sensor
TC:
Thermo Fireplace
V:
Valve
VE:
Open Expansion Tank
VR:
Check Valve
VSP:
1.5 bar Pressurized Safety Valve
VST:
Thermal Relief Valve
1
1" Male-Female Brass Collector
2
1" Ball Valve
3
Circulator with 1½" Fasteners (219660)
4
1" Check Valve (261910)
5
1" Male-Female 3-way Solenoid Valve (143330)
6
Copper Fittings
7
30-plate Heat Exchanger for heat transfer with
the gas boiler circuit (216620)
8
20-plate Heat Exchanger for hot sanitary water
production (205270)
9
¾" Thermal Relief Valve (72940)
10
¾" 1.5 bar Safety Valve (143260)
11
Flow Switch (220830)
12
½" Thermometer Well + Sensor (175960)
13
Electronic Regulator (220780)
A
¾" System Return
B
¾" System Flow
C
¾" Fireplace Return
D
1" Fireplace Flow
E
½" Cold Sanitary Water
½" Hot Sanitary Water
F
SELECTOR FUNCTIONS
Selector: OFF
Everything is switched off
Selector: MAN
Driven Circulator
Valve is set
Selector: AUTO
Circulator is set
Valve is set
Alarm selection
No acoustic signal in the
OFF position
KIT 2
KIT 2
code 261890