Chapter 7. Ordinary maintenance

7.6. Changing the oil and the pump filter

Follow the instructions you can find on the pump manual in order to change the oil and the vacuum pump filter.
However, oils of the VC type shall be used in compliance with the DIN 51506 standards.
It is recommended to use original BUSCH oils of the VM series in compliance with the DIN standards.
The oil you have replaced must be eliminated according to the procedures established by the laws
in force in the country the equipment has been installed.
(20) PLUG FOR OIL DISCHARGE (to completely replace old oil)
(21) OIL FILLING PLUG
(22) VISUAL LEVEL
(figure 7.6. page 53).

7.7. Wiring diagram

(figure 7.7. page 54).
Q1
Main switch
FU1
Pump fuse
FU2
Blade fuse
FU3
Auxiliary trasformer fuse
QM1 Motor contactor
QM2 Blade heater contactor
QV1
Air re-immission valve
QV2
Gas injection airvalve
QV3
Sealing airvalve
M1
Vacuum pump motor
T1
Blade transformer
T2
Aauxiliary transformer
T3
Blade transformer
R1
Blade heater
R2
Blade heater
B0
Limit switch
B1
Gas pressure switch
SE
Electronic board

7.8. Pneumatic diagram

(figure 7.8. page 55).
CV
Vacuum hood
UG
Gas nozzles
BA
Suction pipe union
QV1
Air re-immission valve
QV2
Gas injection airvalve
QV3
Sealing airvalve
B1
Gas pressure switch
BG
Gas cylinder
MP
Pneumatic membrane
M1
Vacuum pump motor
PV
Vacuum pump
S
Sensor

7.9. Disassembling, demolition and elimination of residuals

ATTENTION!
All operations about disassembling and demolition must be done by qualified personnel with mechanical
and electrical expertise required to work in security conditions.
Proceed as follows:
1.
disconnect machine from power mains
2.
disassemble components
3.
remove oil from the pump.
All wastes must be treated, eliminated or recycled according to their classification and to the procedures in force
established by the laws in force in the country the equipment has been installed.