8.1 Fitting the wheels (11)
• Fit the supplied wheels (11) as shown in Figure 5.
8.2 Fitting the supporting foot (8)
• Fit the supplied supporting foot (A) as shown in Figure
6.
8.3 Mains connection
• The compressor is equipped with a mains cable with
shock-proof plug. This can be connected to any 230-
240 V~ 50 Hz shock-proof socket which is protected
by a 16 A fuse.
• Before you use the machine, make sure that the
mains voltage is the same as the operating voltage
(see the rating plate).
• Long supply cables, extensions, cable reels etc.
cause a drop in voltage and can impede motor start-
up.
• At low temperatures below +5°C, sluggishness may
make starting difficult or impossible.
8.4 ON/OFF switch (Fig. 2)
• Pull the ON/OFF switch (13) upwards to switch on the
compressor. To switch off the compressor, press the
ON/OFF switch (13) down.
8.5 Setting the pressure: (Fig. 4)
• Use the pressure regulator (5.1) to set the pressure on
the pressure gauge (5).
• The set pressure can be drawn from the quicklock
coupling (Fig. 1/Pos. 4).
• The vessel pressure can be read off the pressure
gauge (6).
8.6 Setting the pressure switch
• The pressure switch is set at the factory.
Cut-in pressure approx. 6 bar
Cut-out pressure approx. 8 bar.

9. Electrical connection

The electrical motor installed is connected and
ready for operation. The connection complies with
the applicable VDE and DIN provisions.
The customer's mains connection as well as the
extension cable used must also comply with these
regulations.
Damaged electrical connection cable
The insulation on electrical connection cables is often
damaged.
This may have the following causes:
• Passage points, where connection cables are passed
through windows or doors.
• Kinks where the connection cable has been improp-
erly fastened or routed.
• Places where the connection cables have been cut
due to being driven over.
• Insulation damage due to being ripped out of the wall
outlet.
• Cracks due to the insulation ageing.
 www.scheppach.com  service@scheppach.com  +(49)-08223-4002-99  +(49)-08223-4002-58
Such damaged electrical connection cables must not be
used and are life-threatening due to the insulation damage.
Check the electrical connection cables for damage reg-
ularly. Make sure that the connection cable does not
hang on the power network during the inspection.
Electrical connection cables must comply with the ap-
plicable VDE and DIN provisions. Only use connection
cables with the marking „H05VV-F".
The printing of the type designation on the connection
cable is mandatory.
AC motor
• The mains voltage must be 230 V~
• Extension cables up to 25 m long must have a cross-
section of 1.5 mm
.
2
Connections and repairs of electrical equipment
may only be carried out by an electrician.
Please provide the following information in the event
of any enquiries:
• Type of current for the motor
• Machine data - type plate
• Machine data - type plate
10. Cleaning, maintenance, and storage
n
Important!
Pull out the power plug before doing any cleaning and
maintenance work on the equipment. Risk of injury from
electric shock!
n
Important!
Wait until the equipment has cooled down completely!
Risk of burns!
n
Important!
Always depressurize the equipment before carrying out any
cleaning and maintenance work! Risk of injury!
10.1 Cleaning
• Keep the equipment free of dirt and dust as far as
possible. Wipe the equipment with a clean cloth or
blow it down with compressed air at low pressure.
• We recommend that you clean the equipment imme-
diately after you use it.
• Clean the equipment regularly with a damp cloth and
some soft soap. Do not use cleaningagents or sol-
vents; these may be aggressive to the plastic parts
in the equipment. Ensure that no water can get into
the interior of the equipment.
• You must disconnect the hose and any spraying tools
from the compressor before cleaning. Do not clean
the compressor with water, solvents or the like.
10.2 Maintenance work on the pressure vessel/con-
densed water (Fig. 1)
m Important!
To ensure a long service life of the pressure vessel
(7), drain off the condensed water by opening the
drain valve (9) each time after using.
Release the vessel pressure fi rst (see 10.5). Open the
drain screw by turning counter-clockwise (looking at the
screw from the bottom of the compressor) so that all the
condensed water can run out of the pressure vessel.