Gas Connection
Choose fixed connections or use a flexible
pipe in stainless steel in compliance with
the regulation in force. If you use flexible met-
allic pipes, be careful they do not come in
touch with mobile parts or they are not
squeezed.
Flexible nonmetal pipes connection
If it is possible to easily control the connec-
tion in its full area, you can use a flexible
pipe. The flexible pipe must be tightly attach-
ed by clamps.
Installation: use the rubber pipe holder. Al-
ways engage the gasket. Then continue
with the gas connection. The flexible pipe is
prepared for apply when:
– it can not get hot more than room temper-
ature, higher than 30°C;
– it is no longer than 1500 mm;
– it shows no throttles;
– it is not subject to traction or torsion;
– it does not get in touch with cutting
edges or corners;
– it can be easily examined in order to
check its condition.
The control of preservation of the flexible
pipe consists in checking that:
– it does not show cracks, cuts, marks of
burnings on the two ends and on its full
length;
– the material is not hardened, but shows
its correct elasticity;
– the fastening clamps are not rusted;
– expired term is not due.
If one or more defects are visible, do not re-
pair the pipe, but replace it.
Important! When installation is complete,
make sure that the seal of each pipe fitting
is correct. Use a soapy solution, not a flame!
The gas supply ramp is on the rear side of
the control panel.
Warning! Before gas connection
disconnect the mains plug from the
mains socket or switch off the fuse
in the fuse box. Close the primary
valve of the gas supply.
1
1
Gas connection point (only one point is
applicable for appliance)
2
Gasket
3
Adjustable connection
4
LPG rubber pipe holder
The appliance is set to default gas, to
change the setting choose pipe holder
No 4. Always use the gasket sealing
Injectors replacement
1. Remove the pan supports.
2. Remove the caps and crowns of the
burner.
3. With a socket spanner 7 remove the in-
jectors and replace them with the ones
which are necessary for the type of gas
you use.
4. Assemble the parts, follow the same pro-
cedure backwards.
5. Replace the rating label (it is near the
gas supply pipe) with the one for the
new type of gas supply. You can find
this label in the package of the injectors
supplied with the appliance.
If the supply gas pressure is changeable or
different from the necessary pressure, you
must fit an applicable pressure adjuster on
the gas supply pipe.
Adjustment of minimum level
To adjust the minimum level of the burners:
1. Light the burner.
2. Turn the knob on the minimum position.
3. Remove the control knob.
4. With a thin screwdriver, adjust the by-
pass screw position. If you change from
natural gas 20 mbar to liquid gas, fully
electrolux 31
2
3
2
4