DHW 300 - DHW 300+
6
Commissioning
6.1 Domestic hot water system
ATTENTION!
The domestic hot water heat pump must only be operated when filled with
water.
Domestic hot water system requirements
The following materials can be used in the consumer's domestic
hot water system:
Copper
Stainless steel
Brass
Plastic
Depending on the materials used in the domestic hot water sys-
tem (customer installation), material incompatibility may lead to
corrosion damage. This especially applies to zinc-plated materi-
als and materials containing aluminium. If there is a risk of water
contamination during operation, it may be necessary to install a
filter.
Commissioning the domestic hot water system
All installations for the water circuit and air circuit, as well as
all electrical installations, must have been carried out cor-
rectly and fully completed.
Fill the domestic hot water circuit via an external connection.
Purge the domestic hot water circuit (open domestic hot
water taps at the highest extraction points until there are no
more traces of air).
Check the entire domestic hot water system for leaks.
Establish the power supply.
Switch on the heat pump.
The desired domestic hot water temperature (e.g. 45 °C) is
shown on the keypad (Cap. 7 on pag. 8). A corresponding
heat-up time is necessary before the selected temperature
level is reached.
EN-8
7
Operation and function
of the domestic hot
water heat pump
7.1 Operation and display
7.1.1 Description of the key
functions
Key
Menu
Quick heating
Boost
Esc
ESC
OK
UP
DOWN
7.1.2 Description ready display
451905.66.01 · FD 9511
Name
Description
Switches to the main menu, where detailed
settings for the heat pump can be made.
Heating element is activated and works for a
maximum of 4 hours to the domestic hot
water set temperature
Return to the previous menu level
Beginning and completion of a parameter
change / selection of a desired menu item
Value change upwards, or selection menu
and parameters
Value change downwards, or selection
menu and parameters
www.dimplex.de