ERROR CODES
Error Code
TEMP SENSOR OPEN ERROR
It occurs due to a defective sensor, misplaced wires, a defective PCB
and when A/D value that MICOM senses rises over 250.
TEMP SENSOR SHORT ERROR
It occurs due to a defective sensor, misplaced wires, a defective PCB
and when A/D value that MICOM senses falls under 5.
TEMP SENSOR TARGET TEMP
It occurs when the preheating is not completed and the temperature of
cavity inside is under 120 °C for 30 minutes.
ABNORMAL TEMP SENSING ERROR
It occurs when the tmperature of cavity inside is over 250 °C for
10 minutes.
EEPROM OPEN ERROR
It occurs when EEPROM communication is error during initial power
setting.
EEPROM READ & WRITE ERROR
EEPROM use does not occur.
NAK SIGNAL ERROR
NAK signal occurs if initial power-up for more than 10 seconds.
COMMUNICATION ERROR
It occurs when not communicating between main and sub PCB for
more than 10 seconds.
KEY SHORT ERROR
This error occurs when a button is pressed and held for over
60 seconds.
It may occur when water soaks through the inside of the control panel
or dust particles are stuck to TOUCH PAD.
If any of these errors occur, please contact ATAG Customer Service.
General Functions