WARNING! Hazard via electrical current!
The device can cause injuries due to improper installation!
Before installation the local power grid specification should be compared with
that of the device (see type label).
Connect the device only in case of compliance!
Take note of the security advice!

5.2 Installation and connection

ATTENTION!
Any installation, maintenance- and repair jobs must be performed by qualified
personnel only (electrician or refrigeration engineer)!
Discard the complete packing material after unpacking the device. Take out the
provided accessories (Supply and outlet hose, ice scoop, gasket) from the tank.
Place the device on top of an even and safe surface which supports the weight of the
device.
Choose a surface where the ice cube maker is not exposed to direct sunlight, or
close to a direct source of heat such as a cooker, oven or radiator.
Make sure, that a minimum distance of 10 cm is kept between all sides of the device
and the wall and other objects respectively, so that a sufficient air circulation is
provided.
If the ice cube maker is kept outside during the winter and then taken inside for use,
please let it warm up to room temperature before plugging it in.
The electrical circuit in the socket must be secured to at least 16A. Only connect the
device directly to the wall socket; do not use any extension cords or power strips.
Place the device so that the plug is easily accessible and can be quickly removed
from its socket in case of necessity.
Set up the device near water supply connection.
Connect the supply hose to the water tap. The other end of this hose must be plugged
to the connection at the back of the device. Fit the gaskets.
NOTE!
The flow pressure should not exceed 2-3 bar. At higher pressure a pressure
reducer should be connected upstream of the device.
ATTENTION!
The device may be connected to a water connection supplying drink water quality
only. Otherwise, a cleaning unit must be installed in advance.
- 25 -