Prepare Refrigerant Piping - Leroy Merlin S026OEM1 Manuel D'installation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 89
Step 4: Prepare refrigerant piping
The refrigerant piping is inside an insulating
sleeve attached to the back of the unit. You
must prepare the piping before passing it
through the hole in the wall. Refer to the
Refrigerant Piping Connection section of this
manual for detailed instructions on pipe flaring
and flare torque requirements, technique, etc.
1. Based on the position of the wall hole relative
to the mounting plate, choose the side from
which the piping will exit the unit.
2. If the wall hole is behind the unit, keep the
knock-out panel in place. If the wall hole is to
the side of the indoor unit, remove the plastic
knock-out panel from that side of the unit.
(See Fig. 3.3 ). This will create a slot through
which your piping can exit the unit. Use
needle nose pliers if the plastic panel is too
difficult to remove by hand.
Fig. 3.3
CAUTION
Be extremely careful not to dent or damage the piping while bending them away from the
unit. Any dents in the piping will affect the unit's performance.
Knock-out Panel
Fig. 3.4
58
3. Use scissors to cut down the length of the
insulating sleeve to reveal about 15cm (6in)
of the refrigerant piping. This serves two
purposes:
• To facilitate the Refrigerant Piping
Connection process
• To facilitate Gas Leak Checks and enable
you to check for dents
4. If existing connective piping is already
embedded in the wall, proceed directly to
the Connect Drain Hose step. If there is no
embedded piping, connect the indoor unit's
refrigerant piping to the connective piping
that will join the indoor and outdoor units.
Refer to the Refrigerant Piping Connection
section of this manual for detailed instructions.
5. Based on the position of the wall hole
relative to the mounting plate, determine the
necessary angle of your piping.
6. Grip the refrigerant piping at the base of the
bend.
7. Slowly, with even pressure, bend the piping
towards the hole. Do not dent or damage the
piping during the process.
NOTE ON PIPING ANGLE
Refrigerant piping can exit the indoor unit from
four different angles:
Left-hand side
Left rear
Right-hand side
Right rear
Refer to
Fig. 3.4 for details.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

S052oem1S035oem1S071oem1

Table des Matières