GGM AXA2 - Series access control
7.3
System Setting
Master
Standby
Menu
Code
Red Flash
Red
Master
code
*
#
7.4
User optional setting
Master
Standby
Menu
Code
Red Flash
Red
red
41
Master
code
*
42
#
43
Instruction:
1. Master code must be 6-8 digits, Anti-duress PIN must be 8 digits,user PIN is 4-6 digits,The 1
Anti-duress PIN in Zone1 must be 1; The 1
2. The user ID number is any number among 1-2000,Invalid 0 can be omitted; card number must be 8 or 10 digits, if the
card number is less than 8 or 10 digits, input 0 before the card number.
3. Door open time is 0-99 second,0=50mS
4. When register one card user into the device, the device will automatically generate a PIN 1234 , this PIN cant open the
door door.
5. When an invalid master pin is pressed the device will go back to the standby status after 5 seconds, when a valid PIN is
entered it will go back to standby status after 30 seconds.
6. In operating the keypad, pressing # means to confi rm the input digits ,In operation of a cycle adding or deleting cards,
pressing # means to end the cycle operation and back the up operation; pressing * means to exit the operation.
Setting
red
orange
30
0-15#
0#
1#
2#
31
3#
4#
5#
6#
32
26-37#
33
0-2#
34
1-3#
0#
35
1#
2#
Setting
Remarks
orange
0#
1#
0#
1#
2#
0#
1#
st
digit of user PIN and Anti-duress PIN in Zone 2 must be 2.
Remarks
Default 0
When device reset to
factory default ,the
setting is still valid
Default 26
When device reset to
factory default ,the
setting is still valid
Default 1
Default 0
Buzzer will be be in silence except enter the programming mode
Default 1
Buzzer will sound when press the key
Automatic mode,Normally it is off(sleeping mode) but wake up with
Default 2
LED Light Disable when stand-by status
Default 1
5
Functions
To set facility code
Wiegand reader
Standalone for single door (Factory default setting)
Standalone for two doors
With external reader for two doors
Two units interlocked for two doors
Anti-passback for single door
Anti-passback for two door
To set Wiegand format
To set keypad transmission format
To set alarm time
Safe mode 0
Safe mode 1
Safe mode 2
Functions
Disable keypad backlight
Enable keypad backlight
human approach
LED fl ash when stand-by status
st
digit of user PIN and
User Manual
EN