GGM AXA2 - Series access control
EN
4.
Installation
• Remove the back cover from the keypad using the supplied special screw driver
• Drill 2 holes on the wall for the Self tapping screws and I hole for the cable
• Put the supplied rubber bungs to into the two holes
• Fix the back cover fi rmly on the wall with 2 Self tapping screws
• Thread the cable through the cable hole
• Attach the keypad to the back cover.
5.
Wiring
ZONE1
No.
Marks
1
BELL_A
2
BELL_B
3
ALARM+
4
AC2
5
OPEN2
6
D_IN2
7
ALARM2-
8
NO2
9
COM2
10
NC2
Color
Description
Marks
pink
Doorbell button
pink
Doorbell button
red
Alarm anode
black
AC input
yellow
Exit button
OPEN1(LED)
brown
Door contact
D_IN1(BZ)
gray
Alarm 2
ALARM1-
Blue
Relay 2 NO end
purple
Relay2Com
COM1
orange
Relay2 NC end
Color
D0
green
D1
white
AC1
red
GND
black
yellow
brown
gray
NO1
Blue
Purple
NC1
Orange
2
ZONE2
Description
Wiegand output D0
Wiegand output D1
AC1 (+12V)
GND
Exit button (for green LED)
Door contact(for buzzer)
Alarm 1
Relay 1 NO end
Relay1 Com
Relay1 NC end