GGM AXA2 - Series access control
13.5
Add ID user 006, PIN 201200, Zone 2 user
Press
*
201100
13.6
Set open mode of Zone 1 as card+PIN
*
201100
Press
13.7
Rapid increase consecutive numbers 1000 cards (start with 00987865 ID is 005)
*
201100
Press
13.8
Set working mode as reader mode
Press
*
201100
13.9
Set card output format as WG34
Press
*
201100
13.10
Set master open lock 1
press
*
201100
14.
Simple Troubleshooting
Code
Fault
1
Close Read range
Problem
2
in PIN setting
3
PIN can't open door
Alarms at
4
normal condition
No responds
5
after card reading
Keypad light
6
is not bright
Can't enter
7
master mode
#
21
6 # 201200
#
#
13
1
#
.
#
17
00987865 #
05#
#
31
0
#
.
#
32
34
#
.
#
51
.
Fault Cause
Quality of card
1.PIN is not standard
2.Set Password at reader mode
1. use PIN 1234
2. entry mode setting
While installation, light leak under bottom
Units are not in ready mode
Mode of keypad light setting is wrong
Forget master code
.
1000
#
.
1. First number of PIN should be 1 or 2, match with Area number
4. Don't set PIN at reader mode
1. 1234 is original PIN, can't open the door,
should be modifi ed as other PIN
2. Set open mode as entry by card or PIN.
While installation, device should closed to the wall
Press * key, light fl ash, units back to ready mode
1. Set keypad light as shine or auto
2. Under auto mode, light shine after press keypad, delay 30 seconds
Reset to Factory Default, master code will be 999999,
only installer data is restored, user data will not be affected
21
User Manual
Solutions
Use original card
2. PIN shouldn't be 1234
3. PIN is 4 to 6 digits
EN