Installation Procedure; Connection - Atag HEK611 Notice D'utilisation

Publicité

Les langues disponibles

Les langues disponibles

INSTALLATION INSTRUCTION

Installation procedure

Worktop must be placed absolutely horizontal.
Suitably protect the edges of the cut aperture.
Attach the fixing brackets supplied with the device to the
underside of the hob. The assembly method depends on the
thickness of the work top.
Stick the supplied self-adhesive seal to the bottom edges of the
cooking hob.
Insert the hob into the cut aperture. Press the hob firmly towards
the worktop from above.
Attention!
The power rating and required mains voltage are shown on the
rating plate at the back of the oven. Connection should take
place according to national and local regulations.
The seal between the hob and the work surface must be moisture-
proof. The work surface must be absolutely level, as must the hob
of course!
If the work surface is tiled it could be necessary to use liquid
silicone rubber instead of the sealing strip.
If the hob is enclosed between the back and side panels a
minimum distance of 400 mm from these panels should be
observed.
Tighten the mounting clips equally.
A hob should preferably not be positioned immediately above a
refrigerator or freezer built-in below the worktop. If the hob has to
be fitted above a refrigerator or freezer, ensure that the hob is well
insulated.
GB 14
Installation procedure
INSTALLATION INSTRUCTION
General
When the appliance does not have a connecting cable and plug, then
it may be connected to the mains only by an approved installer. After
installation the wall socket and plug must be accessible at all times.
Elektrische aansluiting
The power rating and required mains voltage are shown on the rating
plate at the back of the oven. Connection should take place according
to national and local regulations. This appliance requires 230 V - 50
Hz AC.
The appliance should always be earthed.
Use good quality cable for connecting e.g. H05RRF, 1,5 or 2,5 mm
with 3 or 5 cores, depending on the regulations.
With following colour code:
brown = phase L
blue = phase N
green/yellow = earth ( )
black= neutral or phase
Depending upon the wiring diagram, you can use the black cores for
neutral or a phase.
The cable must have a plug suitable for a nominal load of at least 15 A.
If you want to make a fixed connection, ensure that a multi-pole
switch with a distance between contacts of 3 mm is installed in the
supply cable.
GB 15

Connection

2
,