Super Finish 17ex
4.4
AIR CONNECTION AND GROUNDING
Follow the safety measures provided by the
compressor manufacturer with regard to elec-
trical and general safety. Position the compres-
sor outside of the direct spray area to prevent
the air entry points of the compressor from be-
coming blocked with sprays of paint.
Before connecting the compressed air, turn the
pressure regulating knob to the left until the
stop is reached and switch the multifunction
switch to position 0 (OFF).
1. Connect a suitable pressurized air source/compressor to the
air entry point (6) of the SF 17ex.
Operate the SF 17ex only with filtered and de-
hydrated air.
2. Ground the SF 17ex with the ground cable (7).
4.5
CLEANING PRESERVING AGENT WHEN
STARTING-UP OF OPERATION INITIALLY
Unit with suction tube
1. Immerse the suction system into a container filled with a
suitable cleaning agent (recommendation: water).
Unit with hopper
2. Fill up hopper with a suitable cleaning agent (recommenda-
tion: water).
3. Set multifunction switch (1) to
unit commences to run.
4. Turn the pressure regulating knob (2) to the right until the
stop is reached.
5. Wait until cleaning agent is emitted from the return hose.
6. Turn the pressure regulating knob (2) back approx. one ro-
tation.
In AirCoat mode, set the AirCoat regulator (5) to 0.
7. Set multifunction switch (1) to
Pressure is rising up inside the high pressure hose (visible
at pressure gauge)
8. Point the tip of the spray gun into an open collecting con-
tainer and pull the trigger guard at the spray gun.
9. The pressure is increased by turning the pressure regulating
knob (2) to the right. Set approx. 10 MPa (100 bar) at the
pressure gauge.
10. Spray the cleaning agent out of the unit for approx. 1 - 2 min.
(~1.5 litres) into the open collecting container.
(ON– circulation); the
(spray).
1
6
5
4.6
TAKING THE UNIT INTO OPERATION WITH
COATING MATERIAL
Unit with suction tube
1. Immerse the suction system into a container filled with
coating material.
Unit with hopper
2. Fill coating material into the hopper.
Put the lid on the upper container when in
operation to prevent the coating material
from spraying out of the container.
3. Press inlet valve pusher (4) several times to release pos-
sibly clogged inlet valve
4. Set multifunction switch (1) to
unit will start.
5. Turn the pressure regulating knob (2) to the right until the
stop is reached.
When the noise of the valves changes, the unit is bled and
takes in coating material.
6. If coating material exits from the return hose, turn the
pressure regulating knob (2) back approx. 1 rotation.
7. Set multifunction switch (1) to
Pressure is rising up inside the high pressure hose (visible
at pressure gauge (3)).
8. Pull of the spray gun and spray into an open collecting
container in order to remove the remaining cleaning
agent from the unit. When coating materials exits from
the tip, close the spray gun.
9. Adjust the spraying pressure by turning the pressure reg-
ulating knob (2).
10. Set the required air pressure at the AirCoat regulator (5).
11. The unit is ready to spray.
GB
STARTUP
4
2
3
7
(ON - circulation); the
(spray).
41