GB
SAFETY REGULATIONS
1.9
HIGH-PRESSURE HOSE
Attention, danger of injury by injection! Wear
and tear and kinks as well as usage that is not
appropriate to the purpose of the device can
cause leakages to form in the high-pressure
hose. Liquid can be injected into the skin
through a leakage.
High-pressure hoses must be checked thoroughly before
they are used.
Replace any damaged high-pressure hose immediately.
Never repair defective high-pressure hoses yourself!
Avoid sharp bends and folds: the smallest bending radius
is about 20 cm.
Do not drive over the high-pressure hose. Protect against
sharp objects and edges.
Never pull on the high-pressure hose to move the device.
Do not twist the high-pressure hose.
Do not put the high-pressure hose into solvents. Use only
a wet cloth to wipe down the outside of the hose.
Lay the high-pressure hose in such a way as to ensure that
it cannot be tripped over.
Only use WAGNER original-high-pressure
hoses in order to ensure functionality, safety
and durability.
1.10
ELECTROSTATIC CHARGING (FORMATION OF
SPARKS OR FLAMES)
Electrostatic charging of the unit may occur
during spraying due to the flow speed of the
coating material. These can cause sparks and
flames upon discharge. That is why it is nec-
essary to always ground the device via the
ground cable.
An electrostatic charging of spray guns and the high-pressure
hose is discharged through the high-pressure hose. For this
reason the electric resistance between the connections of the
high-pressure hose must be equal to or lower than 1 MΩ.
Wear appropriate conductive protective clothing (gloves,
shoes, ...).
1.11
VENTILATION WHEN SPRAYING IN ROOMS
Adequate ventilation to ensure removal of the solvent vapors
has to be ensured.
1.12
SUCTION INSTALLATIONS
The are to be provided by the unit user in accordance with the
corresponding local regulations.
34
1.13
EARTHING OF THE OBJECT
The object to be coated must be earthed.
(Building walls are usually earthed naturally)
1.14
CLEANING THE UNIT WITH SOLVENTS
When cleaning the unit with solvents, the sol-
vent should never be sprayed or pumped back
into a container with a small opening (bung-
hole). An explosive gas/air mixture can arise.
The container must be earthed.
1.15
CLEANING THE UNIT
Never spray down the unit with high-pressure
or high-pressure steam cleaners.
Clean the device only with a damp cloth.
Remove deposits from the surfaces in order to
retain conductivity.
1.16
SETUP ON AN UNEVEN SURFACE
The front end must always point downwards in order to avoid
sliding away.
If possible do not use the unit on an inclined surface since the
unit tends to wander through the resulting vibrations.
Super Finish 17ex