Installing to a Solid Concrete Ceiling Structure
WARNING:
The CPA330 is designed to be mounted to a
concrete ceiling with a minimum thickness of 8" and a
maximum drywall covering of 5/8".
WARNING:
Fischer UX10 or AF8 anchors (not provided)
must be installed into structurally sound solid concrete.
Installation into hollow concrete block, mortar, or concrete
that exhibits cracking, spalling, or other defects may result in
failure of anchor and serious personal injury or damage to
equipment.
1.
Using ceiling plate (A) as a template, mark locations of four
pilot holes on ceiling.
2.
Drill pilot holes at marked locations. If using UX10 anchors,
pilot hole diameter will be 3/8". If using AF8 anchors, pilot
hole diameter will be 5/16".
3.
Use four UX10 anchors (not provided) to secure CPA mount
into solid concrete ceiling. (See Figure 3) for dimensions
details.
4.
Place CPA mount over anchors, aligning bolt holes in CPA
mount with installed anchors.
5.
Secure CPA mount to ceiling by installing four 5/16" x 2 3/4"
bolts (not provided) through four 5/16" flat washers (not
provided) and into anchors.
Installing Extension Column
WARNING:
Exceeding the weight capacity can result in
serious personal injury or damage to equipment! It is the
installer's responsibility to make sure the combined weight of
all components located within the mounting system of the
CPA330 does not exceed 500 lbs (226.8 kg).
1.
Route cables through extension column (not included).
2.
Install UL Listed CPA Extension Column Series (not
included) into CPA330.
NOTE:
Installation of hex head self-tapping screws will be
easier when screws are carefully aligned with holes in
extension column, and a drill and nut driver is used. If
a drill will NOT be used, a small amount of pressure will
be needed to get the self-tapping screws started.
3.
Secure extension column to CPA330 using four 5/16-18 x 1"
hex head self-tapping screws (B), four 5/16" split lock
washers (C) and four 5/16" flat washers (D) through holes
in extension column. (See Figure 4)
4.
Install one 5/16" x 1/2" set screw (E) into threaded hole,
tightening firmly against column.
6
(C) x 4
(E) x 1
4
Extension column
(not included)
Figure 4
5.
Complete installation following mount installation
instructions.