The Range Of Environmental Conditions, For Which The Door Has Been Designed; Routine Maintenance Instruction; Restraints In Door Operation; Anti-Drop Dafety Device - Wisniowski UNITHERM SSp Notice De Montage

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 14
Door bolting (lock) - as standard the door is equipped with a lock, which
may be bolted by turning the key counter clockwise 360° (if the door does not
feature a drive unit).
Door unbolting (lock) - use the key or blocking bolt:
• from outside - turn the key 360° clockwise,
• from inside - move upwards the blocking bolt, located next to the lock insert,
and simultaneously turn the handle to the right.
[D000476] 15. THE RANGE OF ENVIRONMENTAL CONDITIONS,
FOR WHICH THE DOOR HAS BEEN DESIGNED
• Resistance to water penetration
• Resistance to wind load
• Thermal resistance
• Air permeability
• Temperature
• Relative humidity
• Electromagnetic fields
(1)
- Refers to manually operated doors. The range of environmental conditions
for the doors with drive is stated in the Assembly and Operating Instruction
of the drive.
[C000050] 16. ROUTINE MAINTENANCE INSTRUCTION
Activities, which may be performed by the Owner after careful
reading of the Instruction supplied with the door:
[A000060] Disconnect the drive power supply during all
maintenance and inspection works.
[C000055] The external door leaf surface shall be cleaned with a sponge and
clean water, or lacquer-cleaning agents available in stores. It is prohibited to use
cleaning agents, which may scratch the door surface, sharp tools, or the nitro
solvent-based cleaning agents, and detergents.
At least once for 6 months carry out the door periodic inspections including:
• Lubricate hinged connections, rollers, springs and guides with e.g. semi-solid
HWS-100 Wurth grease before starting the door and during operation if
needed.
• Do not oil the lock barrel insert. If needed, use the graphite grease.
• During the inspections, check door-to-wall mounting elements, bolts, guiding
rollers. Immediately eliminate any irregularities. It is forbidden to operate the
door, if the irregularities are not eliminated.
• In case of any irregularities or damages of door components, stop using the
door and contact the authorised service centre.
• Check the drive mounting.
[D000231] Clean the stainless steel decoration elements, e.g. with Wurth
cleaning agent for stainless steel, at least two times per month (avoid contact
of the clearing agent with the door leaf).
[C000017] Activities, which may be performed by a Competent
Person having correspondent permissions.
[C000060] The door maintenance should be performed at least once for 12
months. The following activities to be performed during the door routine main-
tenance:
• Check spring tension - for this purpose, open the door leaf by lifting the leaf
to half-open position:
• if the leaf is visibly falling, increase the spring tension by its regulation,
• if the leaf is visibly lifting, decrease the spring tension by its regulation.
• The spring tightening procedure is described in the As-
sembly Recommendations.
• If the above mentioned works are not performed,
there is a risk that the leaf may suddenly drop and
hurt people, or cause damage to objects in its vicinity.
• Check the correct and smooth rotation of rollers during door opening and
closing. If the rollers put resistance or do not rotate at all, check their condi-
tion and rolling surfaces in particular. If necessary, replace entire assem-
blies.
• Check the mechanical components ensuring safety and correct door opera-
tion. In case of any failures, these must be immediately eliminated, and faulty
components and parts should be repaired or replaced.
• When mounting a drive, block the door bolts in its open position, or install
additional devices for automatic bolting.
• Check the condition of suspension cables and springs.
[C000065] Activities, which should be performed by a Profes-
sional Installer:
Any alterations and modifications to the door should be agreed on with
"WIŚNIOWSKI" Sp. z o.o. S.K.A.
Technical description
IIiO/BS/UniTherm/07/2015/ID-95145
Assembly and Operating Instructions – Sectional garage door UniTherm
- class 2
- class 4
- 0,9 W/m
K
2
- class 5
- -30 to +50° C
(1)
- max. 80% not condesated
(1)
- not applicable
(1)
The range of works covered by the door periodical inspection provided by an
authorised service centre of "WIŚNIOWSKI" Sp. z o.o. S.K.A.
• Identify the door type and serial number.
• Check the door marking, warning labels. Add new ones, if missing.
• Check the connection parts used in the door: door-to-wall mounting anchors,
guide mounting bolts.
• Check the springs and elements working with them. In case of evident wear
and tear signs, the elements should be absolutely replaced.
• When the door has been used for longer than 12 years, or if the door have
made more than 20 000 cycles (the number of cycles should be estimated
on the basis of the interview with the door owner) - the springs should be
absolutely replaced.
• Pay attention to conditions, in which the door is operated. If the conditions
are different from the required operation conditions, the owner should be
informed about possible consequences (e.g. about failure occurrence pos-
sibility).
[C000070] The range of works covered by the door periodical in-
spection provided by a Competent Person.
The following activities to be performed during the door routine maintenance:
• Check spring tension - for this purpose, open the door leaf by lifting the leaf
to half-open position:
• if the leaf is visibly falling, increase the spring tension by its regulation,
• if the leaf is visibly lifting, decrease the spring tension by its regulation.
• If the above mentioned works are not performed, there is a risk that the
leaf may suddenly drop and hurt people, or cause damage to objects in
its vicinity.
• Check the correct and smooth rotation of rollers during door opening and
closing. If the rollers put resistance or do not rotate at all, check their condi-
tion, and rolling surfaces in particular. If necessary, replace entire assem-
blies.
• Check the mechanical components ensuring safety and correct door opera-
tion. In case of any failures, these must be immediately eliminated and faulty
components and parts should be repaired or replaced.
[C000045] 17. RESTRAINTS IN DOOR OPERATION
The door is not intended to be used:
• in an explosive environment,
• as a fire-proof partition,
• in moist rooms,
• in rooms with chemical substances harmful to the protective and paint coatings,
• from the sunny side in case of dark-coloured door leaves,
• as a bearing structure of a building,
• as a hermetic barrier.
[D000173] 18. ANTI-DROP SAFETY DEVICE
[A000013] The door with anti-drop safety device can be installed and adjusted
by at least a COMPETENT person.
[A000014] The present Assembly and Operating Instruction is a document in-
tended for Professional Installers or Competent persons. It contains necessary
information to ensure safe installation of the anti-drop safety device.
Please be familiar with all instructions prior to start with assembly. Please read
carefully the present instruction and follow its recommendations. The correct
door operation depends from the proper installation of the door and its anti-
drop safety device to a considerable extend.
[D000090] Application
Anti-drop safety device has been tested and certified with sectional doors of
"WIŚNIOWSKI" Sp. z o.o. S.K.A. It is certified to be used solely in doors pro-
duced by "WIŚNIOWSKI" Sp. z o.o. S.K.A.
"WIŚNIOWSKI" Sp. z o.o. S.K.A. does not bear responsibility for applying
this safety device in another doors. The anti-drop safety device may be used in
all sectional doors manufactured by "WIŚNIOWSKI" Sp. z o.o. S.K.A. which
operate vertically with a drive, or manually-operated.
The device is suitable for doors with the leaf weight from 20kg to 500kg. The safe-
ty device should be installed on both cables, on which the door leaf is hanged.
[D000095] Threats
The cables suspending the door leaf operate under high tension. All assembly
and maintenance works may only be performed, when the spring tension is re-
leased. The spring tension should only be released when the door is in its closed
position. It is critical to follow the safety rules provided in the door maintenance
instruction.
EN
5

Hide quick links:

Publicité

Table des Matières
loading

Produits Connexes pour Wisniowski UNITHERM SSp

Ce manuel est également adapté pour:

Unitherm ssjUnitherm sst

Table des Matières