A
NOTICE!
• After connecting the device to the gas supply, check the gas pipe for
leakage at all the connection points (all threaded connections, hose
connections with clamps, connection to the gas cylinder) using a
foaming agent, e.g. with soap.
• In addition, perform a visual inspection of the hose (for cracks,
weathering, damage).
• Replace any faulty hoses immediately with a new one.
6.7
Connecting a gas cartridge to the ACX40G cooler
!
WARNING!
• Observe the handling and storage instructions for the gas cartridge.
• Make sure that the ports on the cartridge and the cooler are free of
dirt.
I
NOTE
The cooler is suitable for operation with self-sealing gas cartridges of the
type CAMPINGAZ CP250.
➤ Push the gas cartridge up into the port on the cooler (fig. 5, page 6).
!
WARNING!
Never check for leaks with an open flame or near sources of ignition.
➤ Check all connections with leak spray.
There are no leaks at the connections if no bubbles form.
Any time you move the cooler:
➤ take out the gas cartridge first.