IND780 Terminal Division 2 and Zone 2/22 Installation Manual
Harsh Enclosure Cable Glands and Cable
Assignments
Harsh Enclosure Cable Openings
The standard glands and plugs provided with the IND780 Harsh Enclosure are
NOT ATEX-certified for increased safety and therefore not suitable for installation in
a Zone 2/22 environment. IND780 terminals supplied in Europe have ATEX plugs
in their openings, and are shipped with a kit of ATEX glands. For IND780 terminals
supplied elsewhere, METTLER TOLEDO supplies an optional ATEX Glands kit
(#64063383) that has enough ATEX-certified glands and plugs for all connections
to the harsh enclosure. Figure 2-18 and Table 2-2 show the uses and cable size
limits of the various openings in the back of the harsh enclosure, installed using
cable glands from KOP #64063383. The pattern code is included for ease of
reference. It is important to use cables that are within the cable size limits specified
for the glands to ensure proper sealing of the enclosure.
Option 4
Option 3
PLC 1
COM
Figure 2-18: Harsh Enclosure Cable Opening Assignments
Table 2-2: Harsh Enclosure Cable Openings with ATEX Glands KOP #64043383
Pattern
Large 25 mm plastic cable gland,
optional interface connections
Plastic hole plugs, M25 for sealing
unused cable openings
PDX
, 25mm metal cable gland
Analog Load Cell and IDNet, 16 mm
metal cable gland
POWERCELL, 16 mm metal cable
gland
PDX
, 16mm metal cable gland
Scale 3
Scale 2
Scale 1
COM
Scale 4
Description/Use
Option 2
Option 1
A/C
Cable Size
Quantity
Limits (mm)
9 - 16
2
N/A
2
13-16
1
6 - 8
4
8 -10
1
8-10
1
2-23