Technical Data - Bosch GLM 40 Professional Notice Originale

Masquer les pouces Voir aussi pour GLM 40 Professional:
Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 37
24 | English
Continuous measurement
Area measurement
Volume measurement
Simple Pythagoras Measurement
(g)
Memory value display
(h)
Error indicator

Technical data

Digital laser measure
Article number
Measuring range (typical)
Measuring range (typical, unfavourable conditions)
Measuring accuracy (typical)
Measuring accuracy (typical, unfavourable conditions)
Smallest display unit
Operating temperature
Storage temperature
Relative air humidity max.
Max. altitude
Pollution degree according to IEC 61010-1
Laser class
Laser type
Laser beam diameter (at 25 °C) approx.
– 10 m distance
– 40 m distance
Automatic switch-off after approx.
– Laser
– Measuring tool (without measurement)
Weight according to EPTA-Procedure 01:2014
Dimensions
1 609 92A 5DX | (27.01.2020)
GLM 40
3 601 K72 90.
A)
0.15–40 m
B)
20 m
A)
±1.5 mm
B)
±3.0 mm
1 mm
-10 °C to +45 °C
-20 °C to +70 °C
90%
2000 m
C)
2
2
650 nm, < 1 mW
D)
9 mm
D)
36 mm
20 s
5 min
0.09 kg
105 x 41 x 24 mm
Bosch Power Tools