PATTERN can be set upto 3. Choose 1, 2, or 3 with the left or right key in the
"PATTERN SET" and press [ENTER] to get into the PATTERN set up screen.
From the moment "PATTERN 1 SET" is gone for 30 seconds, it memorizes the
MANUAL movements and after 30 seconds it will return to a higher menu. If you
want to finish set up before the 30-second ends, press [ENTER].
5. ALARM SET
It consists of 4 ALARM INPUTs and 3 ALARM OUTs.It can sense an
ALARM input from exterior SENSORs and it performs with PRESET or
PATTERN function and outputs the ALARM OUT signals.
It recognizes the ALARM signal input as an ALARM signal when it
continues more than 150ms for a time and each ALARM movement time
is decided depending on it's correspondence to the DWELL TIME of the
PRESET and PATTERN connected.
* * MAIN MENU * *
CAMERA...
VIDEO SET...
Press
PRESET...
[Enter]
AUTO MODE...
ALARM SET...
OTHER SET...
ALARM PRIORITY SET
This sets the priority of the 4 ALARM inputs so
ALARM can work corresponding to the priority.
The priority of the DEFAULT is ALARM1: 1,
ALARM2: 2, ALARM3: 3, ALARM4: 4, MOTION: 5.
If the ALARM is working at the same time and the
priority is the same, it will operate according to the
DEFAULT priority. While the ALARM is working,
it cannot detect MOTION.
ALARM IN SET
This sets the input TYPE to "NO" (Normal Open),
"NC" (Normal Close), or "OFF" depending on the
features of the SENSOR connected.
3-20
( ALARM SET)
ALARM PRIORITY SET..
ALARM IN SET..
ALARM OUT SET..
ALARM PATTERN SET..
AUX OUT CONTROL..
RET
ALARM PRIORITY
ALARM1
1
ALARM2
2
ALARM3
3
ALARM4
4
EXIT
QUIT
ALARM IN
ALARM1
NO
ALARM2
NC
ALARM3
NO
ALARM4
NC
EXIT
QUIT
ALARM OUT
Each ALARM input corresponds to one of the
3 ALARM OUT.
ALARM PATTERN
This sets the operation of PATTERN movements
when inputting ALARM.
When the ALARM is working, it will stay in the
PRESET location corresponding the ALARM for
the DWELL TIME and the ALARM connected to
the PATTERN will continuously operate the
PATTERN movements.
When the ALARM is inputted the correspondence
will be as follows: ALARM1 input to PRESET 1,
ALARM 2 input to PRESET 2, ALARM3 input to
PRESET 3, ALARM 4 input to PRESET 4, and
MOTION input to PRESET 5.
The OFF in the Setup Menu does not operate the PATTERN, and it
means 1
PATTERN1, 2
PATTERN 2, 3
continuous motion of PATTERN 1 + PATTERN 2, HALF 2
motion of PATTERN 2 + PATTERN 3 and FULL
PATTERN 1+PATTERN2+PATTERN3.
AUX OUT CONTROL
This sets the ALARM OUT motion to continue
or act only when the ALARM is working.
If it is set to OFF the ALARM OUT motion will
operate only when the ALARM is working.
(Active "Low"), and if it's set to ON, the
ALARM OUT will always operate regardless
of the ALARM.
ALARM OUT
ALARM1
1
ALARM2
2
ALARM3
3
ALARM4
2
MOTION
1
EXIT
QUIT
E
ALARM PATTERN
ALARM1
OFF
ALARM2
OFF
ALARM3
1
ALARM4
2
MOTION
3
EXIT
QUIT
PATTERN 3, HALF1
continuous
continuous motion of
AUX OUT
OUT1
OFF
OUT2
OFF
OUT3
ON
EXIT
QUIT
3-21