8.0 TECHNICAL CHARACTERISTICS

Sound alarm device type ...................................................................... Z
Rated supply voltage............................................................................ 13.8 Vdc , 14.4Vdc
Operating voltage (min – max). ............................................................ 9 ÷ 15 Vdc
Absorption at rest ................................................................................. 7 mA
Max alarm absorption ........................................................................... 1600 mA medium; 2500 mA peak
Flash absorption .................................................................................. 6 mA medium; 60 mA peak
Protection module absorption ............................................................... 5 mA
Max control unit absorption .................................................................. 150 mA
Acoustic pressure ................................................................................ > 110 dB (A) @ 1 m
Operating frequency ............................................................................ 1400 ÷ 1600 Hz
Sound timeout ...................................................................................... 15 minutes
Flash light colour .................................................................................. orange
Flash light blinking frequency ............................................................... 1 Hz
Input lock voltage (NC to positive) ........................................................ >7.3 Vdc
Input absorption (NC to positive) .......................................................... 2 mA
Internal battery autonomy in stand-by condition ................................... 36 hours
Low battery threshold ........................................................................... 11.5 Vcc
Siren tamper contact ............................................................................ 1A @ 24V
Protection module tamper contact (solid state relay) ............................ 50 mA @ 50 Vdc ; R typ = 20 Ω
Environment Class ............................................................................... IV
Certified operating temperature ........................................................... -25 °C ÷ +70°C
Max permitted humidity ........................................................................ 93%
Certified enclosure protection degree ................................................... IP44 / IK07
External cover material ........................................................................ Self-extinguishing PC-ABS
Flash cover material ....................................................................................... Self-extinguishing PC-ABS
Optional internal cage material ............................................................. zinc-coated 8/10 sheet
Bottom material .................................................................................... Self-extinguishing PC-ABS
Allocable battery .................................................................................. 12V - 1,9 to 2,2Ah
Dimensions (w x h x d) ......................................................................... 203 x 253 x 87 mm
Weight (without battery) ....................................................................... 1100 g
Connection cable ................................................................................. 4 0,22mm
Tamper ................................................................................................ Opening and removal
Guaranteed performance level (EN50131-4) ........................................ Grade 2
) control units arranged to provide a 14.4V voltage allows the optimum recharge of the internal battery,
*
compensating for the voltage drop of the protecting diode inside the siren.

NOTES CONCERNING EN50131- 4 CERTIFICATION

Importantly, jumper C must be kept intact to allow the siren to sound in case of remote power blackout for the
compliance to EN50131-4. Cutting this jumper will cause loss of compliance.
HPA700P
Compliant with standard: EN50131-4
Rating: Grade 2
Certificate no : 3220900012
IMPORTANT: Batteries must be deemed dangerous wastes
(E.W.C. 160601) and therefore they must be delivered to
authorised disposal operators.
26/36
*
wires + 2 ≥0,50mm
2
2
wires
HPA700P