2.0 INSTALLATION
Open the siren enclosure by unscrewing the front locking screw;
Break the piercing arrangements for cable passage and fasten the siren
to the wall using the provided holes.
Perform connections and programming; use anti-tamper shielded multi-
pole cables.
Lift the micro preventing opening/removal (A) after having freed it from
the adhesive band that blocks it. The screw on which the micro rests is
factory calibrated so that the lever, when there is a cover, closes the
contact. If this is not the case (due to bearing wall irregularities), screw or
unscrew the screw as much as necessary. Close the micro again (B).
Insert the battery into the housing and connects the fastons: red wire to positive, black wire to negative.
The siren performs the initial test (LEDs are turned on for an instant and a beep is emitted), after that
flash LEDs start blinking. Under this condition, the siren does not sound (initial block function). The
arrangement for the correct operation will occur after having applied the "AL" and "S" block signals.
Wall
fastening
hole
Pre-setting
for protection
module
Battery
housing
Cables passage
piercing
arrangem.
Wall
fastening
hole
Use screened multipole cable for burglar alarm systems.
20/36
Drilled riser
for securing
internal cage
Wall
fastening
hole
Drilled riser
for securing
external cover
Drilled risers
for securing
internal cage
HPA700P