PROGRAMMING PROCEDURE (Setting the programmer and the current sensor)
Dip-switch settings DS1
CAUTION:
If you change the dip settings you must memorise
them; press the "PROG"
indicating that the settings have been memorised.
Sequential command TD/CH1
Travel direction inversion only during closing.
Automatic reclosing (DIP 2)
Operation with one or two motors (DIP 3)
Warning light output (DIP 4)
FTCI test (DIP 5)
FTCI test enabled
FTCI test disabled
If you enable the security test you will have to connect both the
transmitter and the receiver to the controlled load output (CTRL
30 Vdc). When the test is enable one second will pass between
receiving a command and carrying it out.
CURRENT SENSOR
The programmer checks the electrical input to the motor,
detecting any eventual increase in effort above the normal
operating limits and intervenes as an additional safety device.
When the sensor intervenes the door automatically inverts the
travel direction.
AUTOMATIC REPOSITIONING
If the programmer blocks due to an encoder count error
a programmer reset
, when the motor has been released
there is a problem with the motor
received (after pre-flashing for 10 seconds) the door automatically
moves, slowly, to the completely closed position (2 times as in the
programming procedure) in order to recover the correct position
At this point the programmer will function normally.
No commands will be accepted during repositioning but the security
devices will cut in and block all movement if they go into alarm.
"TB" or "TD" button.
When you activate the manual release mechanism, move the door
manually, and then relock the door in a position different from the
starting position the programmer will lose control over the position
of the door.
The next time it receives a movement command the programmer
will carry out automatic repositioning to find the travel limit.
obligatory.
ON
1 2 3 4 5
ON
1 2 3 4 5
ON
1 2 3 4 5
ON
1 2 3 4 5
ON
1 2 3 4 5
, after
or
when a command has been
PROG",
PRESS THE PROG BUTTON FOR MORE
THAN 4 SECONDS: THE PAUSE
WILL APPEAR INDICATING THAT YOU ARE
IN THE PAUSE PROGRAMMING MODE
ATTENTION! IF THE DOOR
MOVES IN THE CLOSING
DIRECTION THE MOTOR
CONNECTION IS INCORRECT.
PRESS "PROG" AGAIN TO
CANCEL THE PROGRAMMING
PROCEDURE, INVERT THE
MOTOR CONNECTION (RED AND
BLACK CABLE) AND REPEAT THE
PROGRAMMING PROCEDURE.
WHEN THE DOOR REACHES THE COMPLETELY OPEN POSITION IT
INVERTS THE TRAVEL DIRECTION AND AFTER MOVING FOR A FEW
CENTIMETRES IT WILL OPEN AGAIN TO CONFIRM THE COMPLETELY
OPEN POSITION. AT THIS POINT THE DOOR MOVES IN THE CLOSING DIRECTION. WHEN IT IS
COMPLETELY CLOSED IT INVERTS ITS TRAVEL DIRECTION FOR A FEW
CENTIMETRES AND THEN STARTS CLOSING AGAIN SO AS TO ESTABLISH THE
COMPLETELY CLOSED POSITION.
AFTER HAVING CARRIED OUT THIS MANOEUVRE THE LOGIC CONTROL WILL OPEN THEN
CLOSE THE DOOR COMPLETELY IN ORDER TO CALIBRATE THE CURRENT SENSOR.
THE OPERATION HAS NOT
SUCCEEDED. YOU WILL HAVE
TO REPEAT THE
PROGRAMMING PROCEDURE.
Attention: If an obstacle is detected during the closing
manoeuvre the programmer will carry out one of the follow-
ing work cycles:
1) with automatic reclosing enabled
-
travel direction inverts until the completely open position is
reached
-
after the pause time has elapsed the closing cycle will start.
2) with automatic reclosing disabled
-
travel direction inverts until the completely open position is
reached
-
a pause time of 20 seconds is carried out
-
after the pre-flashing for 10 seconds the closing cycle will
start.
With or without automatic reclosing selected the cycle will be carried
out 3 times consecutively (if parameter drA=1, see page 24) or only
once (if parameter drA=0) after which the garage door will remain
completely open until it receives another command.
During the repositioning manoeuvre the current sensor value
SnS
increase in the door impact force. At the end of the manoeu-
vre, however, it will reset automatically to the chosen value.
23
1...4... sec.
PRESS PROG
THE PAUSE TIME COUNT
WILL START (MIN. 2
SECONDS: MAX 120
SECONDS) INDICATED BY
THE PAUSE
FLASHING ON THE DISPLAY
PRESS PROG
THE PAUSE TIME COUNT
ENDS AND THE DOOR OPENS
SLOWLY IN ORDER TO FIND
THE COMPLETELY OPEN
POSITION.
WHEN THE DOOR REACHES THE
COMPLETELY CLOSED POSITION THE
PROGRAMMER SAVES THE PARAMETERS
AND QUITS THE PROGRAMMING MODE