TERMINAL BOARD CONNECTIONS
1-2
Battery input/output (- and + respectively)
3-4
Courtesy light output (motor 1 and 2: 24Vdc 15 W)
5
Common for all inputs and outputs
6
LAMP 24Vdc 25W output for warning lights, intermittent
activation (50%), 12,5W continuous activation
7
Output powering external loads 30 Vdc
8
Controlled output, powering external loads 30 Vdc
9-10 Common for all inputs and outputs
11-12 Common for all inputs and outputs
13
FTCI (NC contact) Safety and control devices in input
(photocells invert the travel direction when an obstruction
is detected). Opening this contact will provoke a travel
direction inversion during closure due to the cutting in of
the safety device.
14
TB (NC contact) Stop button input (The opening of this
contact interrupts the cycle until a new movement command
is given)
15
TD (NO contact) sequential command button input
16
EMRG1 (NO contact) emergency manoeuvre input 1
17
EMRG2 (NO contact) emergency manoeuvre input 2
18
Common for the emergency buttons
19
Outer conductor for radio receiver antenna
20
Inner conductor for radio receiver antenna (if an external
antenna is fitted use a coaxial type cable RG58 with an
impedance of 50Ω).
Note
(1)
The total of the 2 external device outputs must not exceed 5W.
13
15
20
19
16
18
17
B1
R1
J2
L6
L7
L5
P1
Collegamento encoder a 4 fili
Connecting 4-wire encoder
Branchement encoder à 4 fils
Anschluss der Encoder mit 4 Drähten
Conexionado encoder con 4 conductores
B1
Signal buzzer "via radio" mode
CSER Serial connection (only for diagnostics)
D1
Six-segment LED display
DS1
Selection dip-switch
F1
Fuse 3,15A (24V circuit protection during battery operation)
F2
Fuse 10A (motor power protection during battery operation)
F3
Fuse 8A (motor power protection)
F4
Fuse 3,15A (24V circuit protection)
(1)
14
13
12
11
10
9
8
7
MM
J3
ON
1 2 3 4 5
D1
YELLOW
GREY
GREEN
BLUE
ALL UNUSED NC CONTACTS MUST BE BRIDGED and conse-
quently the security device test must also be deactivated (TFTC
– DIP 5). If you want to activate the FTCI test both the transmis-
sion and receiver parts of the photocell must be connected to the
binding post marked "CTRL 30 Vdc". If the test is active there
will be a 1 second delay between the command transmission and
movement of the door.
(1)
Switch on the power and make sure that the indicator LEDS are in
the following condition:
- L1 Power on
- L2 Wrong battery connection
- L3 Battery charging
- L4 Indicates transmitter code programming
- L5
- L6
- L7 Indicates active sequential command (TD/CH1)
Note
(2)
diately.
(3)
Note
(4)
Note
tive.
Check that the activation of the safety devices (those which have
not been bridged) switch the corresponding LEDS off. If the green
power on
fuses and the power cable connection at the transformer. If one
or more of the safety LEDS do not light up check the contacts
of the relative security devices and check that the unused safety
device contacts have been bridged.
DC0393
6
5
4
3
2
1
BATTERY
IN
L2
L3
P2 L4
P3
DS1
COLORE
CABLE COLOUR
CABLAGGI
CODE
Giallo
Yellow
Grigio
Grey
Verde
Green
Blu
Blue
J1
Transformer secondary connection
J2
Jumper enabling remote transmitter memorisation
J3
Second radio channel selection jumper
MM
Transmitter code memory module TX
P1
Programming button (PROG)
P2
Transmitter code memorization button (MEMO)
P3
Transmitter code cancellation button (DEL)
R1
Radio frequency module, 433 MHz for S449 transmitters
22
FTCI
TB
lit
lit
lit
L1
CS 1226A
YELLOW
L1
GREY
GREEN
BLUE
COLORATION
KABEL-
DES CÂBLAGES
FARBEN
Jaune
Gelb
Gris
Grau
Vert
Grün
Bleu
Blau
lit
off
(2)
(3)
off
off
(4)
lit
(4)
lit
off
-
-
M1
M2
J1
COLORACIÓN
CABLEADOS
Amarillo
Gris
Verde
Azul