FREE COMMISSIONING

If you decide not to use the commissioning help, you should make the necessary settings
in the following sequence:
- Menu 10.
Language
- Menu 3.
Time, date and operating times
- Menu 5
Settings for heat circuit, all settings
- Menu 6.
Protective functions if necessary
- Menu 7.
Special functions if necessary
- Menu 4.2
operating mode „Manual" should be used to test the switch outputs with
the consumers connected, and to check the sensor values for plausibi-
lity. Then switch on automatic mode.
Observe the explanations for the the individual parameters on the following
pages, and check whether further settings are necessary for your application.

MALFUNCTIONS / MAINTENANCE

Do not open the unit until it has been disconnected!
Possible error/information messages:
Sensor x defective ---------------------- >
max. heat circuit -------------------------- >
(Information only)
Restart ------------------------------------------- >
(Information only)
10
MALFUNCTIONS WITH ERROR
MESSAGES
If the controller detects a malfunction, the
red light fl ashes and the warning symbol
also appears in the display. If the error is no
longer present, the warning symbol changes
to an info symbol and the red light no longer fl
ashes. To obtain more detailed information on
the error, press the key under the warning or
info symbol.
Do not try to deal with this
yourself. Consult a specialist in the
event of an error!
Notes for the specialist:
Means that either the sensor, the
sensor input at the controller or the
connecting cable is/was defective.
(Resistance table on page 7)
The maximum heat circuit temperature
set in menu 5.4 was exceeded.
Means that the controller was restar-
ted, for example due to a power failure.
Check the date&time!

MAINTENANCE

In the course of the general annual maintenance of your heating system you
should also have the functions of the controller checked by a specialist and have
the settings optimised if necessary.
Performing maintenance:
- Check the date and time (see menu 3.1)
- Assess/check plausibility of statistics (see menu 2)
- Check the error memory (see menu 2.6)
- Verify/check plausibility of the current measurement values (see menu 1)
- Check the switch outputs/consumers in manual mode (see menu 4.2)
- Poss. optimise the parameter settings
USEFUL NOTES / TIPS AND TRICKS
- The service values (see menu 9.) include not only current measurement values
and operating states, but also all of the settings for the controller.Write
the service values down just once after commissioning has been successfully
completed.
- In the event of uncertainty as to the control response or malfunctions the
service values are a proven and successful method for remote diagnosis. Write
the service values down (see menu 9.) at the time that the suspected malfunction
occurs. Send the service value table by fax or e-mail with a brief description of the
error to the specialist or manufacturer.
- To protect against loss of data, record any statistics and data that are
particularly important to you (see menu 2.) at regular intervals.