Function And Alarm Test - Gigaset elements S30851-H2517-R101 Notice D'utilisation Et De Montage

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

SMOKE ALARM

FUNCTION AND ALARM TEST

Perform a visual inspection of the smoke alarm.
1.
In so doing, check:
The smoke alarm is in place
The smoke inlet openings for coarse dirt (dust, paint)
The smoke alarm for mechanical damage
A damaged smoke alarm must be replaced immediately.
Perform a function test. To do this, press the face of the alarm for at least 1 second.
2.
The signal sounds if the function test is successful.
The smoke alarm is working correctly.
DIN 14676 stipulates that smoke alarms must be replaced with new ones
3.
after 10 years at the latest.
After every function test, alarm muting is enabled automatically for approx.
10 minutes.
NOTE!
Alarm muting has no function when the smoke alarm is tested with
test aerosol.