TECHNICAL DATA
Max. working area
Air flow step 1
Air flow step 2
Dehumidifying at 20˚C and 70% r.h.
Dehumidifying at 30˚C and 80% r.h.
Power at 20˚C and 70% r.h.
Energy consumption at 20˚ and 70% r.h.
Tank volume
Refrigerant
Regrigerant change
Voltage
Frequency
Fuse
IP-class
Dimensions (L x W x H)
*Technical changes and improvements may occur. All values are approximate and may vary depending on external circumstances such as
temperature, ventilation and humidity
PROBLEM
The dehumidifier does not start
The dehumidifier does not start
High noise level/rattling
No condensate water collected
Does not shut off when water tank is full.
Error code E2
If you have a problem with your dehumidifier, refer the troubleshooting guide. If none of the above works, contact your dealer to get your
dehumidifier serviced."
LD40
100 m
2
200 m
/h
3
350 m
/h
3
7,5 L/24h
13 L/24h
180 W
4,3 kWh/24 h
11 l
R290
99 g
230 V
50 Hz
10 A
X1
460 x 345 x 575 mm
REMEDY
• Make sure that the dehumidifier is connected to the socket and that the fuse has not blown.
• If the symbol icon is lit, check that the water tank is empty and correctly seated in the dehumidifier. Make sure the
float hangs freely.
• Check that the value of the humidity in the machine's control panel is displayed by "waking up" the panel. The
dehumidifier must start within 5 minutes if this is higher than the set value.
• Unplug the power cord, wait 10 seconds and reconnect it.
• Make sure the fan wheel is spinning.
• Make sure that the air can flow freely through the dehumidifier. Air emissions and air filters must be clean and the
dehumidifier must be at least 20-30 cm from the wall.
• Listen if the compressor is running, but keep in mind that the dehumidifier may be defrosting cycle and then the
compressor will stop. Start by waiting for about 30 minutes.
• Check that a thick layer of ice does not form on the cooling coils / slats behind the filter.
• Increase the distance between the dehumidifier and surrounding surfaces.
• The cooling coils may make contact to each other and cause vibrations. Disconnect the dehumidifier from the electrical
outlet and separate the loops
• Check that no dirt etc. is deposited on the drip tray underneath the cooling coils, clean if necessary.
• Check that the temperature is above 2 ° C or below 35 ° C.
• It is important that the float hangs freely in the water tank. If it does not, it does not sense the water level is and can
therefore not ensure that the dehumidifier stops
• If E2 is shown in the display, the humidity sensor may be defective. Try unplugging the power cord, wait 10 seconds,
and reconnect it. If the error code persists, contact your dealer.
OPERATION INSTRUCTIONS
LD44
LD48PRO+
140 m
2
160 m
/h
3
300 m
/h
3
11 L/24h
19 L/24h
285 W
8 kWh/24 h
11 l
R290
115 g
230 V
50 Hz
10 A
X1
460 x 345 x 575 mm
EN
180 m
2
160 m
/h
3
300 m
/h
3
16 L/24h
31 L/24h
450 W
9,1 kWh/24 h
11 l
R290
130 g
230 V
50 Hz
10 A
X1
460 x 345 x 575 mm