A
Bypass valve
B
Valve button
C
Pressure regulator
D
On / Off Switch
E
Suction Tube
F
Drain Tube
G
Airless Spray Gun
H
Reversible Spray Tip
J
Tip Guard
K
Gun trigger lock
L
Gun connection thread
M
Gun filter
N
Pump unit
P
Connection thread of the device
Q
Airless Hose
R
Device filter
T
Intake filter
U
Power Cord
V
Easy Access Door
W
Storage container for intake pipe
X
Pump Removal Tool
Z
Inlet Valve Removal Tool
Power Flush Attachment
• In PRIME position, it feeds the coating substance to the drain pipe.
• In SPRAY position it feeds the pressurised substance through the hose
to the gun.
• Automatically relieves system pressure in overpressure situations.
Taps the inlet valve ball when pushed to disengage it.
Increases (clockwise) and reduces (anticlockwise) the operating pressure
in the device system. Align the corresponding symbol on the pressure
regulator with the arrow to select a function.
Turns sprayer ON and OFF.
The coating substance is fed to the pump from the paint pail through the
intake pipe.
The coating substance is drained through the drain pipe when the device
is filled/pressure is relieved.
Coating substance escapes upon pulling the trigger. The substance flow
stops upon release. The device stops.
• Atomises the coating substance and distributes it in a spray pattern
Reduces the risk of injury caused by coating substance injections.
Prevents accidental triggering of spray gun.
Threaded connection with pivoting joint for Airless hose.
Filters the coating substance fed into the spray gun to prevent/reduce the
risk of a clogged tip.
Pumps and pressurises liquids as well as feeds substances to the gun
through the paint hose – special feature: quick and easy to replace if
worn.
Threaded connection for airless hose.
Transports high-pressure fluid from pump to spray gun.
• Filters the coating substance output by the pump to reduce/prevent
clogged tips and create an acceptable surface finish.
• Self cleans only during pressure relief. Clean after each use.
Prevents solids and debris from accessing the pump.
Plugs into power source.
The maintenance flap provides quick access to the pump unit. Pull the
pump flap from the tabs and push upwards to open it.
Holds suction and drain hoses.
Use cut out in the frame to remove/install pump packing.
Cut out in the frame provide the tools to quickly remove/install the inlet
valve without additional tools.
Connects garden hose to suction tube for power flushing water-based
fluids.
163