Technical Data
15
Technical Data
15.1
Unit Data
Cooling power:
Input Voltage:
Current consumption:
Cooling:
Heating:
Refrigerant type:
Refrigerant charge amount:
Dimensions (W x H x D):
Unit:
Control panel:
Panel cutout:
Weight:
15.2
Cable Lengths
Display Cable:
Alternate Air Sensor (optional):
Outside Air Sensor (optional):
All custom cable lengths supplied in
standard 1.5 m increments:
NOTE
I
Maximum length of display and sensor cables is 22.9 m. The outside air
sensor and alternate air sensors are optional items and are not included
with the standard control package.
32
Marine Climate
Marine Climate
System MCS6
System MCS12
6000 BTU/h
12000 BTU/h
1758 W
230 V
2.7 A
3.7 A
R-410A
8.5 oz/241 g
10.5 oz/298 g
229 x 286 x
245 x 337 x
407 mm
81 x 64 x 24 mm
81 x 64 x 24 mm
64 x 48 mm
64 x 48 mm
18 kg
4.5 m Standard
2.0 m Standard
4.5 m Standard
22.5 m Maximum
MCS6, MCS12, MSC16
Marine Climate
System MCS16
16000 BTU/h
3517 W
4689 W
230 V
230 V
3.3 A
4.5 A
4.3 A
5.9 A
R-410A
R-410A
12.5 oz/354 g
286 x 343 x
508 mm
508 mm
81 x 64 x 24 mm
64 x 48 mm
28 kg
28 kg