9. Care and Maintenance

Replacing Batteries
Your scale is equipped with a low battery indicator. If the batteries are weak, ' ' will appear in the LCD
Display and the scale will automatically shut off. In this case, replace the batteries with three new AAA-size
alkaline batteries.
Cleaning
Clean the scale periodically using a damp cloth and, if necessary, a small amount of mild detergent.
Disposal
Observe the local regulations for material disposal. Dispose of the device in accordance with local regulations.
If you have any questions, please contact the local authorities responsible for waste disposal.

10. Troubleshooting Guide

If the scale encounters an error during measurement, the following is displayed:
Display
'
'
'
' runs across the LCD.
or incorrect weight is displa-
yed.
or incorrect weight is displa-
yed.
Incorrect weight is displayed.
No Bluetooth
connection
®
( symbol is missing).

11. FCC Compliance Statement

Changes or modifications not expressly approved by the party responsible for compliance could void the
user's authority to operate the equipment.
Cause
Unknown measurement as it is
outside the user assignment limit
or a unique assignment is not pos-
sible.
The fat percentage is outside the
measurable range (less than 3 %
or greater than 65 %).
The maximum load-bearing capa-
city of 400 lb (181.4 kg) was excee-
ded.
No flat, stable surface.
Not standing still.
Scale zero setting is incorrect.
Device outside the range.
User memory space is full. No
more measurements can be saved.
The batteries in the scale are empty. Replace the batteries of scale.
10
Remedy
Assign unknown measurement in
app or repeat user assignment.
Repeat the measurement barefoot
or, if necessary, moisten the soles
of your feet slightly.
The load must not exceed 400 lb
(181.4 kg).
Place the scale on a flat, stable
surface.
Stand as still as possible.
Wait until the scale switches itself
off. Activate scale, wait for '0.0 lb'
to appear and repeat measure-
ment.
The minimum range in a free field
is approx. 82 ft (25 m). Walls and
ceilings reduce the range.
Other radio waves may interfere
with the transmission. Therefore,
do not position the scale near
devices such as WLAN routers,
microwaves, induction hobs etc.
Open the app. The data is trans-
ferred automatically. This may take
up to one minute.