2,5 cm space
5,0 cm insulation
Flammable material
Please note: that the Aduro 5-1 must be installed on a floor with the adequate load-bearing capacity. If the existing
construction does not meet this requirement, appropriate adaptation measures must be taken (e.g. a load-
distributing plate).
If the fireplace insert is to be placed close to flammable material, such as a wooden floor or carpet, it must be
placed on a non-flammable base. The floor plate should extend for at least 30 cm in front of the fireplace insert, and
15 cm on each side.
2.2 Convection and ventilation
The Aduro 5-1 is built as convection stove. This means that air from the room circulates between the inner stove
and the outer covering. As a result, the heated air is distributed evenly throughout the room. In order to fully exploit
the energy in the wood, however, the heat generated around the fireplace insert and the flue pipe (that connects the
fireplace insert to the insulated chimney) should also be used. The calorific values depend on the length of the
uninsulated flue pipe – initially, the first metre of uninsulated flue pipe will increase the efficiency by approx. 5 %.
There should be at least 25 mm space around the fireplace insert. It is important that the space around the fireplace
insert and the flue pipe is ventilated. There should be ventilation openings of at least 200 cm2 both below and
above the fireplace insert. There are many ways to create ventilation around the flue pipe. Some examples are
given below.
- 16 -