Reset inhibition time input 2
Password
Command
Example
Result
Request status of reset function
Password
Command
Example
Result
Alarm condition time-out input 1
Password
Command
Example
Result
Alarm condition time-out input 2
Password
Command
Example
Result
Request alarm condition time-outs
Command
Example
Result
Alarm SMS content when input 1 tension is high
Password
Command
Example
Result
Alarm SMS content when input 1 tension is low
Password
Command
Example
Result
V. 02 – 15/05/2012
HAMGSM133
TIZ2x
x = 0 (no reset) or 1 (reset)
TIZ20
Inhibition time does not reset on input 2 when input 2 is idle. Default = no
reset
INI?
INI?
Receive the status of the reset function on the inputs.
OSS1:ss
ss = time in seconds (00~59)
OSS:08
The alarm on input 1 must remain for 8 seconds before the alarm is passed
on. Default = 1 second
OSS2:ss
ss = time in seconds (00~59)
OSS2:15
The alarm on input 2 must remain for 15 seconds before the alarm is passed
on. Default = 1 second
OSS?
OSS?
Get a list of the alarm condition time-outs on both inputs.
TIN1A:xxxxxxxx
xxxxxxxx = message (max. 100 characters, all capitals)
TIN1A: TENSION ON INPUT 1
When tension is detected on input 1, an SMS is sent out with text "TENSION
ON INPUT 1". Default: ALARM! INPUT 1 HIGH
Note: a semi colon (;) is not allowed inside the message
TIN1B:xxxxxxxx
xxxxxxxx = message (max. 100 characters, all capitals)
TIN1B1: NO TENSION ON INPUT 1
When no tension is detected on input 1, an SMS is sent out with text "NO
TENSION ON INPUT 1". Default: ALARM! INPUT 1 LOW
Note: a semi colon (;) is not allowed inside the message
11
©Velleman nv