Cleaning, Care And Maintenance; What To Do If; There Is No Hot Water; The Water Fl Ow Rate Is Weak - Stiebel Eltron MEW Utilisation Et Installation

Robinetteries pour ballons d'eau chaude ouverts (a ecoulement libre)
Masquer les pouces Voir aussi pour MEW:
Table des Matières

Publicité

Les langues disponibles

Les langues disponibles

OPERATION | INSTALLATION
OPERATION
The volume of water expands as the water heater is
heated up. Expansion water drips from the tap. This
is a necessary and normal process.
If you use the tap in conjunction with our SNU 5 SL anti-drip
comfort with anti-drip function the expansion water is kept inside
the water heater.
4.
Operation
You can draw water by pulling the lever forward and up.
By pivoting the lever sideways you set the required temperature
through mixing the cold and hot water. Turning it to the right
releases cold water, turning it to the left releases hot water.
5.

Cleaning, care and maintenance

Clean the taps with a damp cloth. Never use abrasive or corrosive
cleaning agents.
Descale the perlator if it is clogged with limescale. Remove it from
the pivoting arm to do this.
6.

What to do if ...

6.1

... there is no hot water

The tap is fully opened. In this case it could be that the water
heater has not heated the water because there is no power. Check
the MCB/fuse and residual current device in your fuse box.
6.2
... the water fl ow rate is weak
It could be that the jet controller in the tap is contaminated or
scaled up. In this case clean the jet controller or descale it. You
can order the jet controller from us as a replacement part with
part number 279932.
6.3

... water is dripping from the tap

When water expands in the water heater expansion water drips
from the tap. This is a normal process.
7.
Safety
7.1
Country-specifi c safety information
All required steps up to and including commissioning must be
carried out by a qualifi ed contractor. During this process, these
installation instructions must be observed.
We guarantee trouble-free function and operational reliability
only if original accessories and spare parts intended for this tap
are used.
7.2

Instructions, standards and regulations

Observe all applicable national and local instructions
!
and regulations, e.g. DIN 1988 and EN 806 in Germany.
www.stiebel-eltron.com
8.
Appliance description
8.1

Standard delivery

The standard delivery is shown in the following diagram. The
pipes connected to taps MEW and MESL are chrome-plated copper
pipes. The pipes on the MES are plain copper.
10
9
8
7
1 Lever
2 Outlet with perlator
3 Tap body
4 Mating fi tting with adapter sleeve
plastic piece (for MES, MESL, shown above)
5 Waste set (MEW)
6 DHW inlet pipe from the water heater
7 Cold water inlet pipe to the water heater
8 Butterfl y valve
9 Cold water inlet pipe to the tap
10 Pull rod (MEW)
9.

Installation conditions

The tap is intended for a static pressure of up to 0.6 MPa. Install
a pressure reducer upstream of the tap in the water mains if the
static pressure is higher.

10. Installation

10.1 Tap

»
Thoroughly fl ush the cold water supply line.
»
Debur the pipes if you have reduced them.
»
Ensure the pipes are not kinked.
»
Place the tap body with the gasket from above into the basin/
sink hole.
1
2
3
4
6
5
MEW | MES | MESL |
9