Y
ou should affix the hood to a wall of sufficient weight-bearing capacity, so not to one
made of plasterboard.
T
he cooker hood must be placed at a minimum distance of 60 cm from the cooking plane for
electric cookers and 60cm for gas or mixed cookers. If the instructions for installation for the gas
hob specify a greater distance, this has to be taken into account.
Do not tile, grout or silicone this appliance to the wall. Surface mounting only. Do not fix chimney
flue to furniture or fly over shelves unless the chimney flue can be easily removed, in case
maintenance is ever required.
T
he cooker hood is provided with an upper air exit B for discharging fumes externally for models
including chimney flue C ( Suction Version A- exhaust pipe not supplied). If cooking fumes and
vapours cannot be externally discharged, the cooker hood can be used in the recirculating version
F: the installation of 1 active charcoal filter F allows the
recirculation of fumes and vapours through the upper grid G.
M
ake sure that there is a power socket near the hood and that the system has a 30 mA differential.
The mains voltage must be the same as that on the label inside the hood. The
hood has a 1250 mm power cable with or without plug: if it does have a plug, connect the hood
to an accessible approved socket; or if it does not (connection direct to the mains), fit an approved
bipolar switch with a minimum contact opening of no less than 3 mm (accessible). This installation
and electrical connection must be executed by a qualified technician.
I
f the cooking top is in use, the cooker hood must always operate.
P
roduct performance test carried out in accordance with standard (EU) No 65/2014-Ref: IEC
61591
Maximum performance is achieved by placing the mobile panels, if any, in the open position.
T
he installation instructions for range hoods with accessible metallic enclosures of class II con-
struction shall include details that indicate the location and maximum permitted lengths for any
fixing or mounting screw or other fixing device that penetrates into the range hood to attach an
accessory such as a facia or duct fitting.
W
here fixing or mounting screws, or other fixing devices are used, that penetrate into the
range hood with an accessible metallic enclosure of class II construction, to attach an accessory,
the instructions shall indicate: Warning: Failure to install the screws or fixing device in accordance
with these instructions may result in electrical hazards.
T
he warning shall be in the same part of the instructions that include details of how to mount
the equipment.