The TPE recognises the new module and needs its address. Using the "arrow up" & "arrow down"
buttons on the TPE the number assigned can be modified and then push the V button to confirm.
It is recommended that the first row of the headend is set as row 1, the second as row 2 and so
on up to the 15th.
Important: It is not possible to assign the same number to two or more rows.
The row is allocated a number so that each module can have an individual address consisting of 2
numbers, the first indicates the row number, the second the position of the module within the row
(see fig.15).
Repeat this operation for each mounting rack installed.
Connect the mains cable supplied in the
rack box to the interconnection module
(see fig. 5 and 6).
After a few seconds the display will light
up and show "00". This means there is no
set address on the interconnection modu-
le. Connect the TPE to the interconnection
module to be programmed using RJ45IN
(see fig.7).