Cps2 12V/80A, 24V/50A, 24V/60A, 48V/30A, 24V/75A - Cristec CPS2 12V/16A Manuel D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 1

2.3 CPS2 12V/80A, 24V/50A, 24V/60A, 48V/30A, 24V/75A

Models
Input
Voltage
Frequency
Current intensity 230/115VCA
Power factor
Efficiency
Input fuses F1/F2
Output
Number of outputs
Overall
rated
current
7%)/Rated power
Load curve
Type of batteries
Regulated and filtered output
voltage
Regulation tolerance before
distributor and fuses
Peak-to-peak ripple and noise
Automotive output fuses
mounted in parallel in the BAT
pole -
Environment
Operating temperature
Cooling
Relative humidity
Case
Material
Paintwork
Dimensions excluding cable
gland (length, height,
depth)/Weight
Fixing centre distances
Wall screw
Protection factor
Board protection
Standards
CE/CEM markings
CE/safety markings
Electrical protection
CPS2/12-80
From 85 to
265VAC single
phase
From 47 to 63Hz
6A/12.6A
0.9 in rated conditions
> 80% in rated conditions
2 x 25A/250V –
6.3x 32
3 separate outputs BAT D, BAT 1 and BAT 2 (integrated distributor). Each output can be used on
its won and supply the entire current
(+/-
80A/1140W
Type of charge selected using internal switch IU or IUoU (Boost, Absorption, Floating – factory
setting)
See switch settings table
See switch settings table. Chargers can operate on DC supply
< 2%
< 500mV
4 x 20A/32V
(F3/F4/F5/F6)
-10°C to +45°C ; +45°C to +60°C with 4% de-rating of rated Power/°C
Draft fan controlled by internal temperature probe 60°C +/-5°C
Up to 70% (95% sans condensation)
Case comprises 3 parts: aluminium frame and steel flap and hood
Mat black, yellow, and grey epoxy coating
350 x 260 x 135mm / 6Kg
328.5 x 154mm
4 M5 round screws
IP21
Protected with water-repellent varnish (marine environment)
NF EN6100-6-1, NF EN6100-6-2, NF EN6100-6-3, NF 6100-6-4
NF EN60950, NF EN603635-2-29
-Against leaking input surges by rupture of VDR (voltage-dependent resistor)
-Against output polarity reversals by rupture of fuses, except 48-Volt models
-Against output short-circuits and surges
-Against abnormal overheating by cutting off the charger (internal temperature probe 90°C)
-Against output surges
CPS2DEA.DOC
CPS2/24-50
CPS2/24-60
From 85 to 265VAC . Output power from 85 to 160VAC =
80%
7.5A/13A
9A/15A
50A/1425W
60A/1710W
< 500mV
< 500mV
2 x 25A/32V
3 x 20A/32V
(F3/F4)
(F3/F4/F5)
CPS2/48-30
65%
65%
9A/15A
2 x 25A/250V – 6.3x 32
30A/1710W
< 1000mV
sans
CPS2/24-75
53%
11.5A/16A
75A/2137W
< 500mV
4 x 20A/32V
(F3/F4/F5/F6)
26

Publicité

Table des Matières
loading

Table des Matières