INSTALLATION
Safety
INSTALLATION
5.
Safety
Only qualified contractors should carry out installation, commis-
sioning as well as maintenance and repair of the product.
5.1
General safety instructions
We guarantee trouble-free function and operational reliability
only if the original accessories and spare parts intended for the
appliance are used.
WARNING Burns
During operation, the tap can reach temperatures in
excess of 60 °C.
5.2
Instructions, standards and regulations
Note
Observe all applicable national and regional regulations
and instructions.
6.
Appliance description
Standard delivery
MEBD illustration
8 7
9
1 Water inlet pipes
2 Tap body
3 Lever
4 Changeover: Hand shower - outlet
5 MEBD: Hand shower with retainer
6 Water supply connector
7 Fixing bracket with gasket (not part of the DCE compact in-
stantaneous water heater set)
10
| MEKD | MEBD
1
2
3
4
6
5
8 Push rosette
9 Spout with aerator
- Plugs (2 pce) for sealing the concealed connections (not part
of the DCE compact instantaneous water heater set)
7.
Installation
7.1
Cold water connection via tap
f Fix the wall connector onto the tap with screws (seal in) and
f
slide the push rosette over the wall connector.
f Secure the tap to the wall plate with screws (seal in).
f
f Where appropriate, seal the instantaneous water heater
f
concealed connections with plugs (not for compact instanta-
neous water heater DCE).
7.2
Cold water connection via the instantaneous
water heater (not via the DCE compact
instantaneous water heater)
f Secure the anchor base on the wall.
f
f Screw the tap body into the anchor base.
f
7.3
Connecting the instantaneous water heater
f Deburr the pipes if you have reduced them.
f
f Insert the water inlet pipes to connect the instantaneous
f
water heater and the tap body.
f Fit the spout with shower hose and the retainer for the hand
f
shower onto the tap body.
8.
Commissioning
f Disconnect the mains fuse/switch off the MCB of the instanta-
f
neous water heater.
f Lift the lever.
f
f Wait until the water is flowing from the spout without
f
bubbles.
f Reconnect the mains fuse/switch on the MCB of the instanta-
f
neous water heater.
www.stiebel-eltron.com