EN
To ensure your system is safe:
- ensure that an area of at least 50 cm in front of the
appliance is clear of objects which might hinder air
circulation (furniture, chairs, etc.);
- position a shelf at least 10 cm above the top of your
radiator;
- use mounting screws suitable for your wall.
15 cm mini
IMPORTANT This appliance should never be installed
with the electrical connection box positioned topside.
Ensure that the bottom of the device is positioned at
least 15 cm above the floor.
ATTENTION
Always turn off the electricity supply (circuit-breaker
+ pilot wire) before making any connections.
IMPORTANT The system must be fitted with an omni-
polar circuit-breaker with a minimum contact opening of
3mm.
NOTE: Electric towel radiators are designed to be covered safely. However, to
ensure that your appliance works efficiently, you are advised not to cover it com-
pletely. Doing so will increase the temperature and cause the internal cutout to
turn off the appliance.
32
2.2 Positioning your appliance
To get the most out of your appliance and enjoy the highest standards of
comfort, we recommend that you install the appliance near places with high heat loss
(windows, doors, etc.) wherever possible.
You will find a complete set of assembly instructions in your appliance's box.
2.3 Connecting the appliance
The technical specifications of your radiator are shown on its nameplate.
Please note these down before installing it and before requesting any after-
sales assistance.
IP XX
XXX–XXX–XXX–XX
OF: XXXXXXXXXX XXXXXX
N CONSTRUCTEUR XXXXXX
When connecting the appliance to the mains, you must observe:
• the voltage indicated on the nameplate;
• conventional colour coding:
N (blue or grey)
L (brown)
Z23010-03
Z23010-03
IP: protection level of your appliance against the
ingress of solid foreign bodies and water spray
230V ~ XXXXW
Voltage and power required for installation
Appliance reference number
Class II: double insulated
OF: serial number
Manufacturer code
– blue or grey: neutral
– brown: live
EN
Neutral
Live
33