Technical Data; Vibrations, Noise And Lightning; Destination And Usage Environment - Minipack-Torre Mailbag Digit Instructions Pour L'installation, L'emploi Et L'entretien

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

Chapter 2. TECHNICAL FEATURES
EN

2.2 TECHNICAL DATA

Machine net weight: 116Kg
Machine overall dimension
Width: 600 mm
Length: 840 mm
Height: 1050 mm
Machine dimensions when packaged
Width: 740 mm
Length: 940 mm
Heigh: 1230 mm
Environmental conditions
Temperature: 0 ÷ 40°C
Relative humidity (not condensed): 90%
Electrical system
Voltage: see data on plate
Frequency: see data on plate
Total power installed: see data on plate
Individual engine power: see electrical diagram
Connection system: monophase + neutral + grounding
Protection level: IP20
Data relative to the product to be packed/wrapped
Width: Min.160 - Max.250 mm
Length: Min.100 - Max.360 mm
Thickness: Up to 15 mm
Production and use restrictions
Production: 20 pieces/minute
Usable films: Transparent or printed polyethyl (version with double photocell). Maximum thickness 30 micron
CAUTION!
The machine was NOT assembled with anti-blast measures, it is assembled with standard features.
It is therefore forbidden to install and operate the machine in environment with risk of blast (explosion).
Do not exceed values or manufacturing limits described above.
Any other use not provided is not compliant with the technical specifications
and therefore is considered "NOT ACCEPTED".

2.3 VIBRATIONS, NOISE AND LIGHTNING

Vibrations
The machine does not send any vibration that can jeopardize stability and precision of the equipmentplaced nearby.
It is therefore compliant with standard ISO-2631
Noise
The machine produces an acoustic pressure level (sound emission) that is lower than 70 dB(A).
Lightning
The work area where the machine is installed must be sufficiently illuminated with natural light and must be equipped
with devices that allow artificial light enough for preserving operator's safety and health. The minimum lighting required to
guarantee a correct reading of symbols and marks is included between 300 and 500 lux.

2.4 DESTINATION AND USAGE ENVIRONMENT

The machine shall operate exclusively within closed environment, where danger of explosion or fire is not present.
The area surrounding the machine shall remain as much as possible dry and free from bulk.
16

Publicité

Table des Matières
loading

Table des Matières