Access To Menus; Parameter Menu - BFT DEIMOS BT-MA Instructions D'utilisation

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 25

ACCESS TO MENUS

Press the OK key
OK
bFt
Control unit software version
qscd ma
OK
No. total manoeuvres
0000
(in hundreds)
0000
No. manoeuvres since latest
00
maintenance (in hundreds)
No. radio control devices
memorised
PArAM
+/-
FINE
- +
+ -
LoGIc
OK
+/-
FINE
- +
FOLLOWING MENUS
FIG. B
88 8 8
[ 00 ]
Preset value
Parameter increment/reduction
/ON
/OFF
or ON/OFF commutation
Press OK key (Enter/confirm)
OK
- +
Menu scrolling
(+ = preceding - = following)
+ -
OK
tcA
- +
OP. T
- +
CLS. T
- +
op. t slow
- +
cls. t slow
- +
norm. op. speed
- +
norm. cls. speed
- +
slow speed
- +
Zone
tcA
OK
- +
3 step
OK
- +
ibl open
OK
- +
OK
photoc. open
- +
OK
tEst Phot
- +
OK
ScA 2ch
- +
OK
preal
- +
OK
hold-to-run
- +
OK
START-CLOSE
- +
OK
fixed code
- +
OK
radio prog
- +
OK
MAStEr
Fig. A
+
OK
[ 010]
OK
[ 080]
OK
[ 080]
OK
[ 050]
OK
[ 050]
OK
[ 15. 0 ]
OK
[ 15. 0 ]
OK
[ 0
]
OK
[ 0
]
OK
ON
[oFF]
OK
OFF
ON
[oFF]
OK
OFF
ON
[oFF]
OK
OFF
ON
[oFF]
OK
OFF
ON
[oFF]
OK
OFF
ON
[oFF]
OK
OFF
ON
[oFF]
OK
OFF
ON
[oFF]
OK
OFF
ON
[oFF]
OK
OFF
ON
[oFF]
OK
OFF
ON
[oFF]
OK
OFF
ON
[oFF]
OK
OFF
LEGENDA
+ -
Simultaneously press the + and - keys.
Simultaneous pressure of the + and – keys
allows you to exit the active menu and return
to the preceding menu; if this takes place at
the main menu level, programming is exited
and the display switched off.
The modifications made are only confirmed if
the OK key is subsequently pressed.
PrG
Message: Programming in progress
KO! message (value or function error)
"Wait" message (enter value or function)
OK
PrG
PrG
OK
OK
PrG
OK
PrG
OK
PrG
PrG
OK
OK
PrG
OK
PrG
OK
PrG

PARAMETER MENU

PrG
TCA (automatic closing time)
value expressed in seconds
(default 10=10s, min 3=3s, max 120=120s)
PrG
Opening Motor torque – value
expressed in % (default 80%, min 1%,
max 99%)
Closing Motor torque – value
PrG
expressed in % (default 80%, min 1%,
max 99%)
Slow-down opening motor torque –
value expressed in % (default 50%, min
PrG
1%, max 99%)
Slow-down closing motor torque –
value expressed in % (default 50%, min
1%, max 99%)
PrG
Fast opening time
value expressed in seconds
(default 15=15s, min 1=1s, max 2=2min)
Fast closing time
PrG
value expressed in seconds
(default 15=15s, min 1=1s, max 2=2min)
Slow-down numerical value
(default 0, min 0, max 3)
PrG
Zone numerical value
(default min 0, max 127)
PrG
PrG
PrG
PrG
PrG
DEIMOS BT-MA Ver. 11 -
23

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Deimos bt + qsc d ma

Table des Matières