BFT DEIMOS BT-MA Instructions D'utilisation page 20

Table des Matières

Publicité

Les langues disponibles
  • FR

Les langues disponibles

  • FRANÇAIS, page 25
ENGLISH
The writing appearing on the display is indicated between round brackets.
Refer to Figures A and B for the configuration procedure.
15.1) Parameters menu
-
Automatic Closing Time (TCA) [ 10s ]
Set the numerical value of the automatic closing time from 3 to 120 s.
-
Opening Motor torque (op. t) [ 80% ]
Set the numerical value of the motor torque between 1% and 99%.
-
Closing Motor torque (cls. t) [ 80% ]
Set the numerical value of the motor torque between 1% and 99%.
-
Slow-down opening motor torque (op. t slow) [ 50% ]
(UNIPRO ⇒ Advanced parameters ⇒ address 8)
Set the numerical value of the motor torque between 1% and 99%.
-
Slow-down closing motor torque (cls. t slow) [ 50% ]
(UNIPRO ⇒ Advanced parameters ⇒ address 9)
Set the numerical value of the motor torque between 1% and 99%.
-
Fast Opening Time (op. speed. time) [ 15 s. ]
(UNIPRO ⇒ Advanced parameters ⇒ address 6)
Set the time ato normal opening speed (not slowed down), ranging from
1 second to 2 mins.
-
Fast Closing Time (cls. speed. time) [ 15 s. ]
(UNIPRO ⇒ Advanced parameters ⇒ address 7)
Set the time to normal closing speed (not slowed down), ranging from 1
second to 2 mins.
Note: The slow-down time, on closing and on opening, is obtained by
timing one manoeuvre, and setting a lower value within this parameter. If,
for example, one manoeuvre lasts 15 seconds, set "normal speed time"
to 12s to obtain 3s of slow-down time.
Slow-down speed (slov speed) [ 0 ]
-
(UNIPRO ⇒ Advanced parameters ⇒ address 5)
Set the slow-down speed by choosing from one of the following values:
0 – slow down disabled
1 – slow down at 50% of normal speed
2 – slow down at 33% of normal speed
3 – slow down at 25% of normal speed
-
Zone (zone) [ 0 ] (UNIPRO ⇒ Advanced parameters ⇒ address 1)
Set the zone number between a minimum value of 0 and a maximum
value of 127. See paragraph on "Serial connection".
15.2) MENU LOGIQUES (logic)
-
TCA (TCA) [ OFF ]
ON
Activates automatic closing
OFF Excludes automatic closing
-
3 Steps (3 step) [ OFF ]
ON
Enables 3-step logic. A Start impulse has the following effects:
door closed:
opens
on opening:
stops and enters TCA (if configured)
door open:
closes
on closing:
stops and reopens
OFF Enables 4-step logic. A Start impulse has the following effects:
door closed:
opens
on opening:
stops and enters TCA (if configured)
door open:
closes
on closing:
stops and does not enter TCA (stop)
after stopping: opens
-
Impulse lock (ibl open) [ OFF ]
ON
The Start impulse has no effect during the opening phase.
OFF The Start impulse becomes effective during the opening or closing phase.
-
Photocells on opening (photc. open) [ OFF ]
ON:
In case of obscuring, this excludes photocell operation on opening.
During the closing phase, it immediately reverses the motion.
OFF: In case of obscuring, the photocells are active both on opening and
on closing. When a photocell is obscured on closing, it reverses the
motion only after the photocell is disengaged.
-
Photocell test (test phot) [ OFF ]
(UNIPRO ⇒ Advanced logics ⇒ address 14)
ON
Activates photocell check
OFF Deactivates photocell check
If this setting is not activated (OFF), it inhibits the photocell checking
function, allowing connection of devices not provided with additional
checking contact.
-
Gate-open or 2nd radio channel warning light (SCA 2ch) [ OFF ]
ON
The output between terminals 14 and 15 is configured as Gate-open
warning light, in this case the 2nd radio channel controls pedestrian
opening.
OFF The output between terminals 14 and 15 is configured as 2nd radio
channel.
-
Prealarm (preal) [ OFF ]
ON
The blinker comes on about 3s before the motors start.
OFF The blinker comes on at the same time as the motors start
-
Hold-to-run control (hold-to-run) [ OFF ]
20 -
DEIMOS BT-MA Ver. 11
INSTALLATION MANUAL
ON
Hold-to-run operation: the manoeuvre continues as long as the control
key is kept pressed.(OPEN-CLOSE)
OFF Impulse operation, according to the 3 or 4 step logic.
-
Start-Close selection (start - close) [ OFF ]
ON
The input between the two terminals 21-22 acts as close
OFF The input between the two terminals 21-22 acts as start
-
Fixed code (fixed code) [ OFF ]
(UNIPRO fi Advanced logics fi address 13)
ON
The receiver is configured for operation in fixed-code mode, see
paragraph on "Radio Transmitter Cloning".
OFF The receiver is configured for operation in rolling-code mode, see
paragraph on "Radio Transmitter Cloning".
-
Radio transmitter programming (radio prog) [ ON ]
(UNIPRO fi Advanced logics fi address 15)
ON
This enables transmitter storage via radio:
1 – First press the hidden key (P1) and then the normal key (T1, T2,
T3 or T4) of a transmitter already memorised in standard mode by
means of the radio menu.
2 – Within 10s press the hidden key (P1) and the normal key (T1, T2,
T3 or T4) of a transmitter to be memorised.
The receiver exits the programming mode after 10s, other new trans-
mitters can be entered before the end of this time.
This mode does not require access to the control panel.
OFF This disables transmitter storage via radio.
The transmitters can only be memorised using the appropriate Radio menu.
-
Master/Slave (Master) [ OFF ] (UNIPRO ⇒ Advanced logics ⇒ address 12)
ON
The control panel is set as Master in a centralised connection.
OFF The control panel is set as Slave in a centralised connection.
15.3) RADIO MENU (RADIO)
-
Add
Allows you to add one key of a radio control device to the receiver
memory; after storage it displays a message showing the receiver
number in the memory location (from 01 to 64).
-
Add Start button (add start)
associates the required key to Start command
-
Add 2ch button (add 2ch)
associates the required key to 2nd radio channel
For transmitters with hidden key, press hidden key P1 (fig. B1A). For
transmitters without hidden key, the key P1 function corresponds
to simultaneously pressing the 4 transmitter keys or, after opening
the battery compartment, bridging the two P1 points by means of a
screwdriver (fig. B1A).
-
Read (read)
Checks one key of a receiver; if stored it displays a message showing
the receiver number in the memory location (from 01 to 64), and the
key number (T1, T2, T3 or T4).
-
Eliminate list (erease 64)
WARNING! Completely removes all memorised radio control devices
from the receiver memory.
-
Receiver code reading (RX code)
This displays the code entered in the receiver.
IMPORTANT NOTE: STICK THE ADHESIVE KEY LABEL ON THE FIRST
MEMORISED TRANSMITTER (MASTER).
In the case of manual programming, the first transmitter assigns the RE-
CEIVER KEY CODE; this code is necessary in order to carry out subsequent
cloning of radio transmitters.
The on-board Clonix incorporated receiver is provided with a number of
advanced functions:
Cloning of master transmitter (rolling-code or fixed code)
Cloning by replacement of transmitters already inserted in the receiver
Management of transmitter database
Management of common receivers
To use these advanced function, refer to the UNIRADIO instructions and the
CLONIX programming guide, supplied with the UNIRADIO device.
15.4) LANGUAGE MENU (language)
Allows you to set the language on the display programmer.
-
ITALIAN (ITA)
-
FRENCH (FRA)
-
GERMAN (DEU)
-
ENGLISH (ENG)
-
SPANISH (ESP)
15.5) DEFAULT MENU (default)
Restores the preset default values on the control unit. After restoring, a new
autoset operation must be carried out.
15.6) DIAGNOSTICS AND MONITORING
The display on the QSC-D panel shows some useful information, both during
normal operation and in the case of malfunctions.

Publicité

Table des Matières
loading

Ce manuel est également adapté pour:

Deimos bt + qsc d ma

Table des Matières