4.5.10
Replacing the head harness
Remove the head harness from the facepiece as follows (Figure J1 on
page 226):
1. Pull the head harness away from the strap on the facepiece.
2. Push the clip on the head harness towards the visor.
Attach the head harness to the facepiece as follows (Figure J2 on
page 226):
Put the clip onto the strap of the head harness, then pull the clip
away from the fastener so that the clip clicks into place.
Make sure that the tab on the strap locks firmly into the hole of the
clip.
5
Transport
Transport the facepiece in a storage box or in the original packaging.
6
Storage
Loosen the straps of the head harness as far as possible.
Make sure that the facepiece is dry.
Store the facepiece in its bag or storage box.
Store the facepiece in a dry, dust-free place where it will not be
deformed.
Keep the facepiece out of direct sunlight and heat.
Storage temperature: 5 °F to 77 °F (-15 °C to 25 °C).
Observe ISO 2230 and national guidelines for storage,
maintenance and cleaning of rubber products.
Dräger rubber products are treated with an agent to protect against
premature ageing which in some cases is visible as a grey-white
coating. This coating can be washed off with a brush and soapy water.
Dräger FPS 7000
(text approved by NIOSH, not approved by any other notified body)
7
Disposal
Dispose of the facepiece according to local waste disposal
regulations.
Transport
223